dc.identifier.citationBogdanoff, V., & Peräjärvi, K. (2023). Improving the Confidence Associated with Passive Total Neutron Counting in the Nuclear Weapon Disarmament Verification Process. <i>ESARDA Bulletin</i>, <i>65</i>, 2-9. <a href="https://doi.org/10.3011/ESARDA.IJNSNP.2023.1" target="_blank">https://doi.org/10.3011/ESARDA.IJNSNP.2023.1</a>
dc.identifier.otherCONVID_182735886
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/86578
dc.description.abstractPassive total neutron counting is an important tool in the nuclear weapon disarmament monitoring and verification process proposed by the International Partnership for Nuclear Disarmament Verification (IPNDV). In the process, neutron measurements of given treaty accountable items (TAIs) are repeated multiple times in different locations and environments, and the measured neutron count rates are expected to remain unchanged. However, neutrons are heavily scattered in the environment, and the change in location or geometry of the environment can produce varying results in neutron measurements which can deteriorate the confidence of passive total neutron counting. In this paper, we have studied different kinds of neutron detection instruments and methods in various environments to determine the effects of the environment on passive total neutron counting and to develop recommendations and procedures to minimize and take these environmental factors into account. As a result, the moderated 3He proportional counter was the most promising type of instrument in terms of how the change in an environment impacted the measured neutron count rates. However, even with the 3He counter, the environmental influence increased rapidly with the source to- detector distance (SDD). For example, with one-meter, two-meter, and three-meter SDDs, the maximum difference in count rates between outdoor and indoor measurements was 10.06(7) percent, 18.6(3) percent, and 28.1(5) percent, respectively. To mitigate the impact of the measurement environment, we propose to use a bare 252Cf reference source measured in the same geometries as the nuclear TAIs to estimate the influence of the environment on the measured neutron count rates. Using this technique in the same conditions as above produces indoor predictions that differ by 2.55(3) percent with a one-meter SDD, 0.334(5) percent with two-meter SDD and 1.93(4) percent with a three-meter SDD from the actual indoor measurements.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherESARDA; European Commission
dc.relation.ispartofseriesESARDA Bulletin
dc.rightsIn Copyright
dc.subject.othernuclear disarmament
dc.subject.otherIPNDV
dc.subject.otherneutron counting
dc.subject.otherneutron scattering
dc.titleImproving the Confidence Associated with Passive Total Neutron Counting in the Nuclear Weapon Disarmament Verification Process
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-202304252689
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange2-9
dc.relation.issn0392-3029
dc.relation.volume65
dc.type.versionpublishedVersion
dc.rights.copyright© Authors 2023
dc.rights.accesslevelopenAccessfi
dc.subject.ysoydinaseet
dc.subject.ysoasevalvonta
dc.subject.ysoaseidenriisunta
dc.subject.ysotaustasäteily
dc.subject.ysomonitorointi
dc.subject.ysoneutronit
dc.subject.ysoilmaisimet
dc.subject.ysosäteilyfysiikka
dc.subject.ysomittauslaitteiden varmentaminen
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p17503
jyx.subject.urihttp://www.yso.fi/onto/yso/p4114
jyx.subject.urihttp://www.yso.fi/onto/yso/p4115
jyx.subject.urihttp://www.yso.fi/onto/yso/p8187
jyx.subject.urihttp://www.yso.fi/onto/yso/p3628
jyx.subject.urihttp://www.yso.fi/onto/yso/p15394
jyx.subject.urihttp://www.yso.fi/onto/yso/p4220
jyx.subject.urihttp://www.yso.fi/onto/yso/p11069
jyx.subject.urihttp://www.yso.fi/onto/yso/p38423
dc.rights.urlhttp://rightsstatements.org/page/InC/1.0/?language=en
dc.relation.doi10.3011/ESARDA.IJNSNP.2023.1
jyx.fundinginformationThis work was financially supported by the Ministry for Foreign Affairs of Finland.
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

In Copyright
Ellei muuten mainita, aineiston lisenssi on In Copyright