Examining stability of independent component analysis based on coefficient and component matrices for voxel-based morphometry of structural magnetic resonance imaging
Zhang, Q., Hu, G., Tian, L., Ristaniemi, T., Wang, H., Chen, H., Wu, J., & Cong, F. (2018). Examining stability of independent component analysis based on coefficient and component matrices for voxel-based morphometry of structural magnetic resonance imaging. Cognitive Neurodynamics, 12(5), 461-470. https://doi.org/10.1007/s11571-018-9484-2
Published in
Cognitive NeurodynamicsAuthors
Date
2018Copyright
© Springer Science+Business Media B.V., part of Springer Nature 2018
Independent component analysis (ICA) on group-level voxel-based morphometry
(VBM) produces the coefficient matrix and the component matrix. The former
contains variability among multiple subjects for further statistical analysis, and the
latter reveals spatial maps common for all subjects. ICA algorithms converge to local
optimization points in practice and the mostly applied stability investigation approach
examines the stability of the extracted components. We found that the practically
stable components do not guarantee to produce the practically stable coefficients of
ICA decomposition for the further statistical analysis.
Consequently, we proposed a novel approach including two steps: 1), the stability
index for the coefficient matrix and the stability index for the component matrix were
examined, respectively; 2) the two indices were multiplied to analyze the stability of
ICA decomposition.
The proposed approach was used to study the sMRI data of Type II diabetes mellitus
group (DM) and the healthy control group (HC). Group differences in VBM were
found in the superior temporal gyrus. Besides, it was revealed that the VBMs of the
region of the HC group were significantly correlated with Montreal Cognitive
Assessment (MoCA) describing the level of cognitive disorder.
In contrast to the widely applied approach to investigating the stability of the
extracted components for ICA decomposition, we proposed to examine the stability of
ICA decomposition by fusion the stability of both coefficient matrix and the
component matrix. Therefore, the proposed approach can examine the stability of ICA
decomposition sufficiently.
...
Publisher
Springer NetherlandsISSN Search the Publication Forum
1871-4080Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/27960846
Metadata
Show full item recordCollections
License
Related items
Showing items with similar title or keywords.
-
Snowball ICA : A Model Order Free Independent Component Analysis Strategy for Functional Magnetic Resonance Imaging Data
Hu, Guoqiang; Waters, Abigail B.; Aslan, Serdar; Frederick, Blaise; Cong, Fengyu; Nickerson, Lisa D. (Frontiers Media, 2020)In independent component analysis (ICA), the selection of model order (i.e., number of components to be extracted) has crucial effects on functional magnetic resonance imaging (fMRI) brain network analysis. Model order ... -
Removal of site effects and enhancement of signal using dual projection independent component analysis for pooling multi‐site MRI data
Hao, Yuxing; Xu, Huashuai; Xia, Mingrui; Yan, Chenwei; Zhang, Yunge; Zhou, Dongyue; Kärkkäinen, Tommi; Nickerson, Lisa D.; Li, Huanjie; Cong, Fengyu (Wiley-Blackwell, 2023)Combining magnetic resonance imaging (MRI) data from multi-site studies is a popular approach for constructing larger datasets to greatly enhance the reliability and reproducibility of neuroscience research. However, the ... -
Enhancing Performance of Linked Independent Component Analysis : Investigating the Influence of Subjects and Modalities
Xu, Huashuai; Li, Huanjie; Kärkkäinen, Tommi; Cong, Fengyu (IEEE, 2023)In recent years, neuroimaging studies have increasingly been acquiring multiple modalities of data. The benefit of integrating multiple modalities through fusion lies in its ability to combine the unique strengths of each ... -
Tensor clustering on outer-product of coefficient and component matrices of independent component analysis for reliable functional magnetic resonance imaging data decomposition
Hu, Guoqiang; Zhang, Qing; Waters, Abigail B.; Li, Huanjie; Zhang, Chi; Wu, Jianlin; Cong, Fengyu; Nickerson, Lisa D. (Elsevier BV, 2019)Background. Stability of spatial components is frequently used as a post-hoc selection criteria for choosing the dimensionality of an independent component analysis (ICA) of functional magnetic resonance imaging (fMRI) ... -
Multivariate Independent Component Analysis Identifies Patients in Newborn Screening Equally to Adjusted Reference Ranges
Kouři,l Štěpán; de Sousa, Julie; Fačevicová Kamila; Gardlo, Alžběta; Muehlmann, Christoph; Nordhausen, Klaus; Friedecký, David; Adam, Tomáš (MDPI, 2023)Newborn screening (NBS) of inborn errors of metabolism (IEMs) is based on the reference ranges established on a healthy newborn population using quantile statistics of molar concentrations of biomarkers and their ratios. ...