Ultra-high doses tests on 28nm CMOS technology for high energy physics application
Tekijät
Päivämäärä
2024Tekijänoikeudet
Julkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.
This work is about the qualification of next generation of electronics detectors for high
energy physics application. A new upgrade of the Large Hadron Collider, designated as
High Luminosity Large Hadron Collider, is scheduled for completion around 2030 and
applications specific integrated circuits will be exposed to new ultra-high radiation
radiations levels. In comparison to the Large Hadron Collider, where the maximum
expected total ionizing dose is limited to a few tens of Mrad after 10 years of experiment,
while the high luminosity maximum radiation dose is predicted to be significantly
higher for certain chips, reaching above 2.5 Grad. This total ionizing dose is
approximately a hundred times greater and reaches new horizons in radiation
electronics engineering.
In this study, the 28nm complementary metal-oxide semiconductor has been subjected
to testing thanks to specific chip that allow to irradiated single diode or transistors. In
Chapter 3, three tests were conducted on diode inside field oxides field effect transistor
structure. The first test reaches a 1Grad total ionizing dose while the other two only
100Mrad. The second and third test were made at different biases and temperatures
respectively. Results of these tests indicate that the damage to the diode is greater when
the applied voltages and temperature conditions are higher.
The second test was conducted on transistors, and different transistors sizes i.e. W/L =
100/30 𝑛𝑚 and W/L = 3/0.03 𝜇𝑚 and W/L = 0.1/1 𝜇𝑚 where W and L stand for the
width (W) and the length (L) of the transistors respectively. These transistors were
subjected to irradiation at a total ionizing dose of 5 Grad with the objective of evaluating
their survivability. As a result, all n-doped and p-doped metal oxide semi-conductor
transistors survived i.e. a significant current from drain to source is flowing, except the
long and narrow p-doped devices which reached a degradation of 99%. Finally, n-doped
device got a strong increase in the leakage current between 10 thousand to 1 million
more than the pre-irradiation one.
Overall, the 28 nm complementary metal oxide semi-conductor is a promising
technology to make application specific integrated circuits for new detectors generation
for high energy physics applications. However, this report is not exhaustive and a lot of
more tests are needed.
...
Asiasanat
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Pro gradu -tutkielmat [29537]
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Robustness of radiation beam profile measurements
Nykänen, Topi (2023)In this master’s thesis, profile measurements of PTW Semiflex 3D and PTW Semiflex ionisation chambers in addition to IBA MatriXX matrix detector were compared to each other using different measurement set-ups. The ionisation ... -
Assessment of Proton Direct Ionization for the Radiation Hardness Assurance of Deep Submicron SRAMs Used in Space Applications
Coronetti, Andrea; Garcìa Alìa, Rubén; Wang, Jialei; Tali, Maris; Cecchetto, Matteo; Cazzaniga, Carlo; Javanainen, Arto; Saigné, Frédéric; Leroux, Paul (IEEE, 2021)Proton direct ionization from low-energy protons has been shown to have a potentially significant impact on the accuracy of prediction methods used to calculate the upset rates of memory devices in space applications for ... -
Dosimetry study in an X-ray irradiator : Monte Carlo simulations and experimental results on radio-photoluminescence samples
Alem, Abrham (2023)Matter’s exposure to ionizing radiations leads to a variety of possible interactions. Depending on the specific interaction type, energy can be deposited into matter via different mechanisms. The quantification of the ... -
Total ionizing dose analysis of SAR ADC for space applications
Lim, Nadia (2024)This study investigates the performance of a Successive Approximation Register (SAR) Analog-to-Digital Converter (ADC) under Total Ionizing Dose (TID) conditions, identifying the TID-sensitive blocks and their impact on ... -
Analysis of the photoneutron field near the THz dump of the CLEAR accelerator at CERN with SEU measurements and simulations
Lerner, Giuseppe; Coronetti, Andrea; Kempf, Jean Mael; Garcia Alia, Ruben; Cerutti, Francesco; Prelipcean, Daniel; Cecchetto, Matteo; Gilardi, Antonio; Farabolini, Wilfrid; Corsini, Roberto (Institute of Electrical and Electronics Engineers (IEEE), 2022)We study the radiation environment near the THz dump of the CLEAR electron accelerator at CERN, using FLUKA simulations and Single Event Upset measurements taken with 32 Mbit ISSI SRAM memories. The main focus is on the ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.