Plasma response to amplitude modulation of the microwave power on a 14 GHz electron cyclotron resonance ion source
Neben, D., Tarvainen, O., Kronholm, R., Koivisto, H., Kalvas, T., Machicoane, G., & Leitner, D. (2018). Plasma response to amplitude modulation of the microwave power on a 14 GHz electron cyclotron resonance ion source. In J. Lettry, E. Mahner, B. Marsh, R. Pardo, & R. Scrivens (Eds.), Proceedings of the 17th International Conference on Ion Sources (Article 040012). AIP Publishing. AIP Conference Proceedings, 2011. https://doi.org/10.1063/1.5053286
Published in
AIP Conference ProceedingsAuthors
Date
2018Copyright
© AIP Publishing. 2018
This paper reports the effects of sinusoidal microwave power Amplitude Modulation (AM) on the performance of Electron Cyclotron Resonance (ECR) ion sources. The study was conducted on the 14 GHz ECR ion source ECR2 at the University of Jyväskylä. The klystron output was intentionally altered by a variable frequency sinusoidal amplitude modulation. The average microwave power 350 W was modulated between 530 W and 180 W from 0.011-25 kHz. The integrated x-ray energy, the mass analyzed beam current and the forward and reflected microwave power were measured. The energy integrated x-ray signal responded strongly with low frequency modulation and was no longer observable at approximately 2.2 kHz where the signal strength became solely dependent on the time averaged power. The beam current responded in a similar way but exhibited a strong dependence with magnetic field. Qualitatively, we found source tuning parameters where AM effects were reduced also produced the highest currents of Ne8+ in Continuous Wave (CW) mode. Furthermore, these parameters are typically used for optimized beam injection into the K130 cyclotron. The dependence of beam current and the x-ray signal modulation on AM frequency for different magnetic fields are reported. A qualitative interpretation of the results will be given.
...
Publisher
AIP PublishingParent publication ISBN
978-0-7354-1727-4Conference
International Conference on Ion SourcesIs part of publication
Proceedings of the 17th International Conference on Ion SourcesISSN Search the Publication Forum
0094-243XPublication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/28652945
Metadata
Show full item recordCollections
License
Related items
Showing items with similar title or keywords.
-
The effect of microwave power on the Ar9+ and Ar13+ optical emission intensities and ion beam currents in ECRIS
Kronholm, Risto; Sakildien, M.; Neben, D.; Koivisto, Hannu; Kalvas, Taneli; Tarvainen, Olli; Laulainen, J.; Jones, P. (AIP Publishing, 2018)The production of Ar9+ and Ar13+ ions in an ECRIS plasma and the efficiency of the ion beam extraction and transport of the resulting Ar9+ and Ar13+ ion beams have been studied with the JYFL 14 GHz ECRIS by using optical ... -
Influence of axial mirror ratios on the kinetic instability threshold in electron cyclotron resonance ion source plasma
Toivanen, V.; Bhaskar, B. S.; Koivisto, H.; Maunoury, L.; Tarvainen, O.; Thuillier, T. (American Institute of Physics, 2022)Electron Cyclotron Resonance (ECR) ion source plasmas are prone to kinetic instabilities. The onset of the instabilities manifests as emission of microwaves, bursts of electrons expelled from the plasma volume, and the ... -
Experimental evidence on microwave induced electron losses from ECRIS plasma
Sakildien, M.; Tarvainen, Olli; Kronholm, Risto; Izotov, I.; Skalyga, V.; Kalvas, Taneli; Jones, P.; Koivisto, H. (AIP Publishing LLC, 2018)The balance between warm and hot (>1 keV) electron density and their losses from the magnetic confinement system of an Electron Cyclotron Resonance Ion Source (ECRIS) plasma is considered to be one of the main factors ... -
The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source
Tarvainen, Olli; Orpana, J.; Kronholm, Risto; Kalvas, Taneli; Laulainen, Janne; Koivisto, Hannu; Izotov, I.; Skalyga, V.; Toivanen, V. (American Institute of Physics, 2016)The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the ... -
Slit extraction and emittance results of a permanent magnet minimum-B quadrupole electron cyclotron resonance ion source
Kosonen, Sami; Kalvas, Taneli; Koivisto, Hannu; Tarvainen, Olli; Toivanen, Ville (Elsevier, 2024)We present an experimental and simulation study of high charge state ion beams produced with a permanent magnet electron cyclotron resonance ion source (ECRIS) with minimum-B quadrupole magnetic field topology and slit ...