Characterization and performance of the DTAS detector
Guadilla, V., Tain, J. L., Algora, A., Agramunt, J., Äystö, J., Briz, J. A., Cucoanes, A., Eronen, T., Estienne, M., Fallot, M., Fraile, L. M., Ganioğlu, E., Gelletly, W., Gorelov, D., Hakala, J., Jokinen, A., Jordan, D., Kankainen, A., Kolhinen, V., . . . Zakari-Issoufou, A.-A. (2018). Characterization and performance of the DTAS detector. Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment, 910, 79-89. https://doi.org/10.1016/j.nima.2018.09.001
Julkaistu sarjassa
Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated EquipmentTekijät
Rice, S. |
Päivämäärä
2018Tekijänoikeudet
© 2018 Elsevier B.V.
DTAS is a segmented total absorption -ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption -ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of -delayed neutron emitting nuclei.
...
Julkaisija
Elsevier BVISSN Hae Julkaisufoorumista
0168-9002Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/28258301
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons
Guadilla, V.; Algora, A.; Tain, J. L.; Agramunt, J.; Äystö, Juha; Briz, J. A.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Fallot, M.; Fraile, L. M.; Ganioğlu, E.; Gelletly, W.; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Jordan, D.; Kankainen, Anu; Kolhinen, Veli; Koponen, Jukka; Lebois, M.; Martinez, T.; Monserrate, M.; Montaner-Pizá, A.; Moore, Iain; Nácher, E.; Orrigo, S. E. A.; Penttilä, Heikki; Pohjalainen, Ilkka; Porta, A.; Reinikainen, Juuso; Reponen, Mikael; Rinta-Antila, Sami; Rubio, B.; Rytkönen, Kari; Shiba, T.; Sonnenschein, Volker; Valencia, E.; Vedia, V.; Voss, Annika; Wilson, J. N.; Zakari-Issoufou, A.-A. (North-Holland, 2017)In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic β-detector with cylindrical geometry. Since energy deposition simulations differ from the ... -
Overview of High-Performance Timing and Position-Sensitive MCP Detectors Utilizing Secondary Electron Emission for Mass Measurements of Exotic Nuclei at Nuclear Physics Facilities
Ge, Zhuang (MDPI, 2024)Timing and/or position-sensitive MCP detectors, which detect secondary electrons (SEs) emitted from a conversion foil during ion passage, are widely utilized in nuclear physics and nuclear astrophysics experiments. This ... -
The ALICE Transition Radiation Detector: Construction, operation, and performance
ALICE Collaboration (Elsevier B.V., 2018)The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD ... -
Design and characterization of a plastic scintillation detector system for Beta tagging
Li, Xin (2019)The aim of this work is to test the detection performance of the PVT-based plastic scintillation detector system for detection of 𝛽 particles in future recoil-𝛽 tagging studies at JYFL. Characterization of the detector ... -
The detection efficiency of the clover Ge-detectors array at the RITU-GREAT facility
Girka, Anastasiia (2015)Absolute detection efficiency depending upon its position along the beam line is determined for three germanium detectors, that are part of the GREAT spectrometer at the RITU separator focal plane. The efficiency is ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.