Overview of High-Performance Timing and Position-Sensitive MCP Detectors Utilizing Secondary Electron Emission for Mass Measurements of Exotic Nuclei at Nuclear Physics Facilities

Abstract
Timing and/or position-sensitive MCP detectors, which detect secondary electrons (SEs) emitted from a conversion foil during ion passage, are widely utilized in nuclear physics and nuclear astrophysics experiments. This review covers high-performance timing and/or position-sensitive MCP detectors that use SE emission for mass measurements of exotic nuclei at nuclear physics facilities, along with their applications in new measurement schemes. The design, principles, performance, and applications of these detectors with different arrangements of electromagnetic fields are summarized. To achieve high precision and accuracy in mass measurements of exotic nuclei using time-of-flight (TOF) and/or position (imaging) measurement methods, such as high-resolution beam-line magnetic-rigidity time-of-flight (B𝜌-TOF) and in-ring isochronous mass spectrometry (IMS), foil-MCP detectors with high position and timing resolution have been introduced and simulated. Beyond TOF mass measurements, these new detector systems are also described for use in heavy ion beam trajectory monitoring and momentum measurements for both beam-line and in-ring applications. Additionally, the use of position-sensitive timing foil-MCP detectors for Penning trap mass spectrometers and multi-reflection time-of-flight (MR-TOF) mass spectrometers is proposed and discussed to improve efficiency and enhance precision.
Main Author
Format
Articles Review article
Published
2024
Series
Subjects
Publication in research information system
Publisher
MDPI
The permanent address of the publication
https://urn.fi/URN:NBN:fi:jyu-202411147263Use this for linking
Review status
Peer reviewed
ISSN
1424-8220
DOI
https://doi.org/10.3390/s24227261
Language
English
Published in
Sensors
Citation
  • Ge, Z. (2024). Overview of High-Performance Timing and Position-Sensitive MCP Detectors Utilizing Secondary Electron Emission for Mass Measurements of Exotic Nuclei at Nuclear Physics Facilities. Sensors, 24(22), Article 7261. https://doi.org/10.3390/s24227261
License
CC BY 4.0Open Access
Funder(s)
Research Council of Finland
European Commission
Research Council of Finland
Funding program(s)
Research costs of Academy Research Fellow, AoF
ERC Consolidator Grant
Academy Research Fellow, AoF
Akatemiatutkijan tutkimuskulut, SA
ERC Consolidator Grant
Akatemiatutkija, SA
Research Council of FinlandEuropean CommissionEuropean research council
Funded by the European Union. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the European Education and Culture Executive Agency (EACEA). Neither the European Union nor EACEA can be held responsible for them.
Additional information about funding
We thank the support by the Academy of Finland under the Finnish Centre of Excellence Programme 2012–2017 (Nuclear and Accelerator Based Physics Research at JYFL) and projects No. 354589, No. 345869, and No. 345869. The support by the European Union’s Horizon 2020 research and innovation program under grant No. 771036 (ERC CoG MAIDEN) is acknowledged.
Copyright© 2024 by the authors. Licensee MDPI, Basel, Switzerland.

Share