Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons
Guadilla, V., Algora, A., Tain, J. L., Agramunt, J., Äystö, J., Briz, J. A., Cucoanes, A., Eronen, T., Estienne, M., Fallot, M., Fraile, L. M., Ganioğlu, E., Gelletly, W., Gorelov, D., Hakala, J., Jokinen, A., Jordan, D., Kankainen, A., Kolhinen, V., . . . Zakari-Issoufou, A.-A. (2017). Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 854, 134-138. https://doi.org/10.1016/j.nima.2017.02.047
Julkaistu sarjassa
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentTekijät
Päivämäärä
2017Tekijänoikeudet
© 2017 Elsevier B.V. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic β-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis.
Julkaisija
North-HollandISSN Hae Julkaisufoorumista
0168-9002Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/26556012
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Characterization and performance of the DTAS detector
Guadilla, V.; Tain, J. L.; Algora, A.; Agramunt, J.; Äystö, Juha; Briz, J. A.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Fallot, M.; Fraile, L. M.; Ganioğlu, E.; Gelletly, W.; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Jordan, D.; Kankainen, Anu; Kolhinen, Veli; Koponen, Jukka; Lebois, M.; Meur, L. Le; Martinez, T.; Monserrate, M.; Montaner-Pizá, A.; Moore, Iain; Nácher, E.; Orrigo, S. E. A.; Penttilä, Heikki; Pohjalainen, Ilkka; Porta, A.; Reinikainen, Juuso; Reponen, Mikael; Rice, S.; Rinta-Antila, Sami; Rubio, B.; Rytkönen, Kari; Shiba, T.; Sonnenschein, Volker; Sonzogni, A. A.; Valencia, E.; Vedia, V.; Voss, Annika; Wilson, J. N.; Zakari-Issoufou, A.-A. (Elsevier BV, 2018)DTAS is a segmented total absorption -ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory ... -
Detector contamination monitoring system for Finnish radiation early warning network
Bogdanoff, Ville (2020)Tässä pro gradu -tutkielmassa kehitettiin ilmaisimen pinnan kontaminaation mittausjärjestelmää Suomen ulkoisen säteilyn valvontaverkon uuden sukupolven säteilymittausaseman gammailmaisimeen. Ydinvoimalaonnettomuuksissa ja ... -
Development of a telescope detector for Sr-90 detection
Hussain, Junaid (2022)Nuclear catastrophes and accidents release harmful fission products containing long-lived (Se-79, Zr-93, Tc-99, Pd-107, Sn-126, I-129, and Cs-135) radioisotopes having half-life of hundreds of thousands or millions of years ... -
Design and characterization of a plastic scintillation detector system for Beta tagging
Li, Xin (2019)The aim of this work is to test the detection performance of the PVT-based plastic scintillation detector system for detection of 𝛽 particles in future recoil-𝛽 tagging studies at JYFL. Characterization of the detector ... -
Study of the β decay of fission products with the DTAS detector
Guadilla, V.; Algora, A.; Tain, J. L.; Agramunt, J.; Äystö, Juha; Briz, J. A.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Fallot, M.; Fraile, L. M.; Canioglu, E.; Gelletly, W.; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Jordan, D.; Kankainen, Anu; Kolhinen, Veli; Koponen, Jukka; Lebois, M.; Martinez, T.; Monserrate, M.; Montaner-Piza, A.; Moore, Iain; Nacher, E.; Orrigo, S. E. A.; Penttilä, Heikki; Pohjalainen, Ilkka; Porta, A.; Reinikainen, Juuso; Reponen, Mikael; Rinta-Antila, Sami; Rubio, B.; Rytkönen, Kari; Shiba, T.; Sonnenschein, Volker; Sonzogni, A. A.; Valencia, E.; Vedia, V.; Voss, Annika; Wilson, J. N.; Zakari-Issoufou, A.-A. (Jagellonian University, 2017)Total Absorption Spectroscopy measurements of the β decay of 103Mo and 103Tc, important contributors to the decay heat summation calculation in reactors, are reported in this work. The analysis of the experiment, performed ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.