Isometric endurance test of the cervical flexor muscles : reliability and normative reference values
Ylinen, J., Salo, P., Järvenpää, S., Häkkinen, A., & Nikander, R. (2017). Isometric endurance test of the cervical flexor muscles : reliability and normative reference values. Journal of Bodywork and Movement Therapies, 21(3), 637-641. https://doi.org/10.1016/j.jbmt.2017.02.006
Julkaistu sarjassa
Journal of Bodywork and Movement TherapiesPäivämäärä
2017Tekijänoikeudet
© 2017 Elsevier Ltd. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
Objective
To obtain reference values for the isometric endurance test (IET) of the cervical flexor muscles, investigate its reproducibility, and compare the results with the maximal isometric strength test (MIST) of the cervical flexor muscles.
Design
Cross-sectional non-comparative study with single group repeated measurements.
Methods
Altogether 219 healthy females aged 20–59 years volunteered to participate in the study. The IET was performed in the supine position and MIST seated. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and an analysis described by Bland and Altman. The relationship between the two measuring methods was evaluated by Pearson's correlation coefficient.
Results
The mean (SD) IET time was 60 (33) seconds with no significant differences between the age groups of each decade. The ICC for intrarater repeatability was 0.80. However, the Bland-Altman analysis suggested moderate variation in repeated measurements. Pearson's correlation coefficient between the IET and MIST was 0.56.
Conclusion
Normative reference values for the IET are presented. Although the ICC showed good repeatability, one should consider that the change at follow-up visits has to be considerable to be clinically relevant. The correlation between the endurance time and maximal flexion strength was moderate. Thus IET of the cervical flexor muscles may be used in the clinic like the Biering-Sorenson test has been used to assess fatigue of the trunk extensor muscles.
...
Julkaisija
Elsevier; Churchill LivingstoneISSN Hae Julkaisufoorumista
1360-8592Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/26901154
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Liikuntatieteiden tiedekunta [3139]
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Test-retest reliability of motor-evoked potentials at 20% and 60% of maximum isometric voluntary contraction in rectus femoris muscle
Gomez-Guerrero, Gonzalo; Avela, Janne; Enroth, Miro; Häkkinen, Ella; Ansdell, Paul; Howatson, Glyn; Walker, Simon (Elsevier BV, 2023) -
Aging and strength training influence knee extensor intermuscular coherence during low- and high-force isometric contractions
Walker, Simon; Avela, Janne; Wikgren, Jan; Meeusen, Romain; Piitulainen, Harri; Baker, Stuart; Parviainen, Tiina (Frontiers Research Foundation, 2019)Aging is associated with reduced maximum force production and force steadiness during low-force tasks, but both can be improved by training. Intermuscular coherence measures coupling between two peripheral surface ... -
EMG and force production of the flexor hallucis longus muscle in isometric plantarflexion and the push-off phase of walking
Peter, Annamaria; Hegyi, Andras; Stenroth, Lauri; Finni Juutinen, Taija; Cronin, Neil (Pergamon; American Society of Biomechanics, 2015)Large forces are generated under the big toe in the push-off phase of walking. The largest flexor muscle of the big toe is the flexor hallucis longus (FHL), which likely contributes substantially to these forces. This study ... -
Use of deeper plantar flexor muscles in low torque isometric and concentric plantar flexion tasks
Oksanen, Hermanni (2016)Coordination of a task such as plantar flexion might seem simple, but is in reality achieved through the activation of several muscles—muscles that play an important role in locomotion and posture control. These can be ... -
Intrarater Reliability and Analysis of Learning Effects in the Y Balance Test
Kattilakoski, Olli; Kauranen, Noora; Leppänen, Mari; Kannus, Pekka; Pasanen, Kati; Vasankari, Tommi; Parkkari, Jari (MDPI AG, 2023)While the general reliability of the Y balance test has been previously found to be excellent, earlier reviews highlighted a need for a more consistent methodology between studies. The purpose of this test–retest intrarater ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.