Näytä suppeat kuvailutiedot

dc.contributor.authorYlinen, Jari
dc.contributor.authorSalo, Petri
dc.contributor.authorJärvenpää, Salme
dc.contributor.authorHäkkinen, Arja
dc.contributor.authorNikander, Riku
dc.date.accessioned2017-08-08T08:50:19Z
dc.date.available2018-03-04T22:45:07Z
dc.date.issued2017
dc.identifier.citationYlinen, J., Salo, P., Järvenpää, S., Häkkinen, A., & Nikander, R. (2017). Isometric endurance test of the cervical flexor muscles : reliability and normative reference values. <i>Journal of Bodywork and Movement Therapies</i>, <i>21</i>(3), 637-641. <a href="https://doi.org/10.1016/j.jbmt.2017.02.006" target="_blank">https://doi.org/10.1016/j.jbmt.2017.02.006</a>
dc.identifier.otherCONVID_26901154
dc.identifier.otherTUTKAID_73219
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/55018
dc.description.abstractObjective To obtain reference values for the isometric endurance test (IET) of the cervical flexor muscles, investigate its reproducibility, and compare the results with the maximal isometric strength test (MIST) of the cervical flexor muscles. Design Cross-sectional non-comparative study with single group repeated measurements. Methods Altogether 219 healthy females aged 20–59 years volunteered to participate in the study. The IET was performed in the supine position and MIST seated. The reproducibility was evaluated by the intraclass correlation coefficient (ICC) and an analysis described by Bland and Altman. The relationship between the two measuring methods was evaluated by Pearson's correlation coefficient. Results The mean (SD) IET time was 60 (33) seconds with no significant differences between the age groups of each decade. The ICC for intrarater repeatability was 0.80. However, the Bland-Altman analysis suggested moderate variation in repeated measurements. Pearson's correlation coefficient between the IET and MIST was 0.56. Conclusion Normative reference values for the IET are presented. Although the ICC showed good repeatability, one should consider that the change at follow-up visits has to be considerable to be clinically relevant. The correlation between the endurance time and maximal flexion strength was moderate. Thus IET of the cervical flexor muscles may be used in the clinic like the Biering-Sorenson test has been used to assess fatigue of the trunk extensor muscles.
dc.language.isoeng
dc.publisherElsevier; Churchill Livingstone
dc.relation.ispartofseriesJournal of Bodywork and Movement Therapies
dc.subject.othernon-specific neck pain
dc.subject.otherendurance strength
dc.subject.othermaximal strength
dc.subject.otherisometric contraction
dc.subject.otherintrarater reliability
dc.titleIsometric endurance test of the cervical flexor muscles : reliability and normative reference values
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-201708033404
dc.contributor.laitosLiikuntatieteellinen tiedekuntafi
dc.contributor.laitosFaculty of Sport and Health Sciencesen
dc.contributor.oppiaineFysioterapiafi
dc.contributor.oppiaineGerontologia ja kansanterveysfi
dc.contributor.oppiainePhysiotherapyen
dc.contributor.oppiaineGerontology and Public Healthen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2017-08-03T09:15:19Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange637-641
dc.relation.issn1360-8592
dc.relation.numberinseries3
dc.relation.volume21
dc.type.versionacceptedVersion
dc.rights.copyright© 2017 Elsevier Ltd. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.subject.ysoniska
dc.subject.ysokipu
jyx.subject.urihttp://www.yso.fi/onto/yso/p12866
jyx.subject.urihttp://www.yso.fi/onto/yso/p14193
dc.relation.doi10.1016/j.jbmt.2017.02.006
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot