Study of the β decay of fission products with the DTAS detector
Guadilla, V., Algora, A., Tain, J. L., Agramunt, J., Äystö, J., Briz, J. A., Cucoanes, A., Eronen, T., Estienne, M., Fallot, M., Fraile, L. M., Canioglu, E., Gelletly, W., Gorelov, D., Hakala, J., Jokinen, A., Jordan, D., Kankainen, A., Kolhinen, V., . . . Zakari-Issoufou, A.-A. (2017). Study of the β decay of fission products with the DTAS detector. Acta Physica Polonica B, 48(3), 529-532. https://doi.org/10.5506/APhysPolB.48.529
Published in
Acta Physica Polonica BAuthors
Date
2017Copyright
© 2017 the Authors and Jagiellonian University. This is an open access article distributed under the terms of the Creative Commons Attribution License.
Total Absorption Spectroscopy measurements of the β decay of 103Mo and 103Tc, important contributors to the decay heat summation calculation in reactors, are reported in this work. The analysis of the experiment, performed at IGISOL with the new DTAS detector, show new β intensity that was not detected in previous measurements with Ge detectors.
Publisher
Jagellonian UniversityISSN Search the Publication Forum
0587-4254Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/26986301
Metadata
Show full item recordCollections
License
Except where otherwise noted, this item's license is described as © 2017 the Authors and Jagiellonian University. This is an open access article distributed under the terms of the Creative Commons Attribution License.
Related items
Showing items with similar title or keywords.
-
Total Absorption Spectroscopy of Fission Fragments Relevant for Reactor Antineutrino Spectra Determination
Briz, J. A.; Zakari-Issoufou, A.-A.; Fallot, M.; Porta, A.; Algora, A.; Tain, J.L.; Valencia, E.; Rice, S.; Guadilla, V.; Agramunt, J.; Äystö, Juha; Bowry, M.; Bui, V.M.; Caballero-Folch, R.; Cano-Ott, D.; Cormon, S.; Cucoanes, A.; Elomaa, Viki-Veikko; Eronen, Tommi; Estévez, E.; Estienne, M.; Farrelly, G.F.; Fraile, L.M.; Ganioglu, E.; Garcia, A.; Gelletly, W.; Gomez-Hornillos, M.B.; Gorlychev, V.; Hakala, Jani; Jokinen, Ari; Jordan, M.D.; Kankainen, Anu; Kondev, F.G.; Lebois, M.; Martinez, T.; Mendoza, E.; Molina, F.; Montaner, A.; Moore, Iain; Nácher, E.; Orrigo, S.; Penttilä, Heikki; Pérez, A.B.; Podolyak, Zs.; Regan, P.H.; Rissanen, Juho; Rubio, B.; Shiba, T.; Sonzogni, A.; Vedia, V.; Weber, Christine; Wilson, J. (Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, 2016)The contribution of each fission fragment to the reactor antineutrino spectra was determined using the summation method based on the existing information on fission yields and decay data contained in nuclear databases and ... -
Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons
Guadilla, V.; Algora, A.; Tain, J. L.; Agramunt, J.; Äystö, Juha; Briz, J. A.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Fallot, M.; Fraile, L. M.; Ganioğlu, E.; Gelletly, W.; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Jordan, D.; Kankainen, Anu; Kolhinen, Veli; Koponen, Jukka; Lebois, M.; Martinez, T.; Monserrate, M.; Montaner-Pizá, A.; Moore, Iain; Nácher, E.; Orrigo, S. E. A.; Penttilä, Heikki; Pohjalainen, Ilkka; Porta, A.; Reinikainen, Juuso; Reponen, Mikael; Rinta-Antila, Sami; Rubio, B.; Rytkönen, Kari; Shiba, T.; Sonnenschein, Volker; Valencia, E.; Vedia, V.; Voss, Annika; Wilson, J. N.; Zakari-Issoufou, A.-A. (North-Holland, 2017)In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic β-detector with cylindrical geometry. Since energy deposition simulations differ from the ... -
High-accuracy mass spectrometry of fission products with Penning traps
Kankainen, Anu; Äystö, Juha; Jokinen, Ari (Institute of Physics, 2012)Mass measurements of fission products based on Penning-trap technique are reviewed in this article. More than 300 fission products have been measured with JYFLTRAP, ISOLTRAP, CPT, LEBIT and TITAN Penning traps with a typical ... -
Photodynamics studies of ligand-protected gold nanoclusters by using ultrafast transient infrared spectroscopy
Mustalahti, Satu (University of Jyväskylä, 2015)Highly monodisperse samples of three ligand-protected gold nanoclusters Au102(pMBA)44, Au144(SC2H4Ph)60, and a cluster tentatively identified as Au130(pMBA)50, were characterized by UV/vis and infrared spectroscopy, ... -
Characterization and performance of the DTAS detector
Guadilla, V.; Tain, J. L.; Algora, A.; Agramunt, J.; Äystö, Juha; Briz, J. A.; Cucoanes, A.; Eronen, Tommi; Estienne, M.; Fallot, M.; Fraile, L. M.; Ganioğlu, E.; Gelletly, W.; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Jordan, D.; Kankainen, Anu; Kolhinen, Veli; Koponen, Jukka; Lebois, M.; Meur, L. Le; Martinez, T.; Monserrate, M.; Montaner-Pizá, A.; Moore, Iain; Nácher, E.; Orrigo, S. E. A.; Penttilä, Heikki; Pohjalainen, Ilkka; Porta, A.; Reinikainen, Juuso; Reponen, Mikael; Rice, S.; Rinta-Antila, Sami; Rubio, B.; Rytkönen, Kari; Shiba, T.; Sonnenschein, Volker; Sonzogni, A. A.; Valencia, E.; Vedia, V.; Voss, Annika; Wilson, J. N.; Zakari-Issoufou, A.-A. (Elsevier BV, 2018)DTAS is a segmented total absorption -ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory ...