Show simple item record

dc.contributor.authorFinogeev, D. A.
dc.contributor.authorGrigoriev, V. A.
dc.contributor.authorKaplin, V. A.
dc.contributor.authorKaravichev, O. V.
dc.contributor.authorKaravicheva, T. L.
dc.contributor.authorKonevskikh, A. S.
dc.contributor.authorKurepin, A. B.
dc.contributor.authorKurepin, A. N.
dc.contributor.authorLoginov, V. A.
dc.contributor.authorMayevskaya, A. I.
dc.contributor.authorMelikyan, Yu. A.
dc.contributor.authorMorozov, I. V.
dc.contributor.authorSerebryakov, D. V.
dc.contributor.authorShabanov, A. I.
dc.contributor.authorSlupecki, Maciej
dc.contributor.authorTikhonov, A. A.
dc.contributor.authorTrzaska, Wladyslaw
dc.date.accessioned2017-04-27T06:48:28Z
dc.date.available2017-04-27T06:48:28Z
dc.date.issued2017
dc.identifier.citationFinogeev, D. A., Grigoriev, V. A., Kaplin, V. A., Karavichev, O. V., Karavicheva, T. L., Konevskikh, A. S., . . . Trzaska, W. (2017). Performance study of the fast timing Cherenkov detector based on a microchannel plate PMT. In <em>Proceedings of the 2nd International Conference on Particle Physics and Astrophysics</em> (pp. 012168). Journal of Physics: Conference Series, 798. IOP Publishing. <a href="https://doi.org/10.1088/1742-6596/798/1/012168">doi:10.1088/1742-6596/798/1/012168</a>
dc.identifier.otherTUTKAID_73499
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/53707
dc.description.abstractPrototype of the fast timing Cherenkov detector, applicable in high-energy collider experiments, has been developed basing on the modified Planacon XP85012 MCP-PMT and fused silica radiators. We present the reasons and description of the MCP-PMT modification, timing and amplitude characteristics of the prototype including the summary of the detector's response on particle hits at oblique angles and MCP-PMT performance at high illumination rates.
dc.language.isoeng
dc.publisherIOP Publishing
dc.relation.ispartofProceedings of the 2nd International Conference on Particle Physics and Astrophysics
dc.relation.ispartofseriesJournal of Physics: Conference Series;798
dc.subject.otherCherenkov detectors
dc.titlePerformance study of the fast timing Cherenkov detector based on a microchannel plate PMT
dc.typeconferenceObject
dc.identifier.urnURN:NBN:fi:jyu-201704131998
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.type.urihttp://purl.org/eprint/type/ConferencePaper
dc.date.updated2017-04-13T15:15:08Z
dc.type.coarconference paper
dc.description.reviewstatuspeerReviewed
dc.relation.issn1742-6588
dc.type.versionpublishedVersion
dc.rights.copyright© the Authors, 2017. This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence.
dc.rights.accesslevelopenAccessfi
dc.rights.urlhttps://creativecommons.org/licenses/by/3.0/
dc.relation.doi10.1088/1742-6596/798/1/012168


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

© the Authors, 2017. This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence.
Except where otherwise noted, this item's license is described as © the Authors, 2017. This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence.