Study of the Planacon XP85012 photomultiplier characteristics for its use in a Cherenkov detector
Abstract
Main properties of the multi-anode microchannel plate photomultiplier to be used in
a Cherenkov detector are discussed. The laboratory test results obtained using irradiation of the
MCP-PMT photocathode by picosecond optical laser pulses with different intensities (from
single photon regime to the PMT saturation conditions) are presented.
Main Authors
Format
Conferences
Conference paper
Published
2016
Series
Subjects
Publication in research information system
Publisher
Institute of Physics Publishing Ltd.
The permanent address of the publication
https://urn.fi/URN:NBN:fi:jyu-201607013434Käytä tätä linkitykseen.
Review status
Peer reviewed
ISSN
1742-6588
DOI
https://doi.org/10.1088/1742-6596/675/4/042016
Conference
International Conference on Particle Physics and Astrophysics
Language
English
Published in
Journal of Physics: Conference Series
Is part of publication
ICPPA-2015 : International Conference on Particle Physics and Astrophysics, 5–10 October 2015, Moscow, Russia
Citation
- Grigoryev, V. A., Kaplin, V. A., Karavicheva, T. L., Kurepin, A. B., Maklyaev, E. F., Melikyan, Y. A., Serebryakov, D. V., Trzaska, W., & Tykmanov, E. M. (2016). Study of the Planacon XP85012 photomultiplier characteristics for its use in a Cherenkov detector. In I. Arkhangelskaja, & P. Buzhan (Eds.), ICPPA-2015 : International Conference on Particle Physics and Astrophysics, 5–10 October 2015, Moscow, Russia. Institute of Physics Publishing Ltd.. Journal of Physics: Conference Series, 675. https://doi.org/10.1088/1742-6596/675/4/042016
Copyright© the Authors, 2016. Published under licence by IOP Publishing Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution 3.0 licence.