Näytä suppeat kuvailutiedot

dc.contributor.authorNgumba, Elijah
dc.contributor.authorKosunen, Päivi
dc.contributor.authorGachanja, Anthony
dc.contributor.authorTuhkanen, Tuula
dc.date.accessioned2016-11-21T11:28:13Z
dc.date.available2017-08-16T21:45:08Z
dc.date.issued2016
dc.identifier.citationNgumba, E., Kosunen, P., Gachanja, A., & Tuhkanen, T. (2016). A multiresidue analytical method for trace level determination of antibiotics and antiretroviral drugs in wastewater and surface water using SPE-LC-MS/MS and matrix-matched standards. <i>Analytical Methods</i>, <i>8</i>(37), Article 6720-6729. <a href="https://doi.org/10.1039/C6AY01695B" target="_blank">https://doi.org/10.1039/C6AY01695B</a>
dc.identifier.otherCONVID_26254984
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/51935
dc.description.abstractAn analytical method for simultaneous determination of seven commonly used antibiotics and three antiretrovirals in surface water and urban wastewater at the ng L−1 level has been developed. The method involves concentration and clean-up by solid phase extraction (SPE) followed by identification and quantification by liquid chromatography tandem mass spectrometry (LC-ESI-MS/MS). The use of matrix-matched calibration curves constructed by spiking surface water was evaluated for quantification and compared with the internal standard method using isotopically labelled compounds. The method gave absolute recoveries of 41–116% with most of the compounds having recoveries >50%. The LOQs ranged from 5 to 63 ng L−1 allowing for the determination of the analytes at trace levels in the environmental samples considered. The difference in the quantification results obtained using surface water matrix-matched standards and internal standards was within a ±20% margin. The method provides an affordable and relatively fast alternative with acceptable accuracy and precision. The method was applied to study the occurrence of the target analytes in the surface water of Lake Päijänne and wastewater from the Jyväskylä wastewater treatment plant (WWTP) in Central Finland. All target compounds were detected in the WWTP streams with concentrations ranging between 10 and 570 ng L−1 while low ng L−1 levels were measured for some of the analytes in surface waters. The results institute the need for further monitoring in other WWTP streams and receiving waters as well as improvements of the wastewater treatment process with the aim of minimizing the pharmaceutical load in the effluents.
dc.language.isoeng
dc.publisherRSC Publications
dc.relation.ispartofseriesAnalytical Methods
dc.subject.otherwastewater
dc.subject.otherantiretroviral drugs
dc.subject.othersolid phase extraction
dc.subject.otherliquid chromatography tandem mass spectrometry
dc.titleA multiresidue analytical method for trace level determination of antibiotics and antiretroviral drugs in wastewater and surface water using SPE-LC-MS/MS and matrix-matched standards
dc.typeresearch article
dc.identifier.urnURN:NBN:fi:jyu-201611184665
dc.contributor.laitosBio- ja ympäristötieteiden laitosfi
dc.contributor.laitosDepartment of Biological and Environmental Scienceen
dc.contributor.oppiaineYmpäristötiedefi
dc.contributor.oppiaineEnvironmental Scienceen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2016-11-18T10:15:15Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn1759-9660
dc.relation.numberinseries37
dc.relation.volume8
dc.type.versionacceptedVersion
dc.rights.copyright© The Royal Society of Chemistry 2016. This is a final draft version of an article whose final and definitive form has been published by RSC. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.type.publicationarticle
dc.subject.ysopintavesi
dc.subject.ysoantibiootit
jyx.subject.urihttp://www.yso.fi/onto/yso/p11704
jyx.subject.urihttp://www.yso.fi/onto/yso/p10820
dc.relation.doi10.1039/C6AY01695B
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot