Näytä suppeat kuvailutiedot

dc.contributor.advisorFerrari, Prof. Matteo
dc.contributor.advisorGirard, Prof. Sylvain
dc.contributor.authorAlem, Abrham
dc.date.accessioned2023-10-02T05:48:23Z
dc.date.available2023-10-02T05:48:23Z
dc.date.issued2023
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/89326
dc.description.abstractMatter’s exposure to ionizing radiations leads to a variety of possible interactions. Depending on the specific interaction type, energy can be deposited into matter via different mechanisms. The quantification of the absorbed dose in matter is crucial to monitor the radiation levels and asses radiation effects in matter in different application areas such as radiation therapy, particle accelerators, space applications, and high-energy nuclear radiation facilities. The stochastic nature of radiation-matter interaction often requires the use of Monte Carlo tools in dosimetry applications. In the present work, a commercial X-ray irradiator is modeled using PHITS general Monte Carlo tool, aiming at verifying the possibility of using it for the irradiation of various types of macroscopic samples at high doses, ranging between the kGy and the MGy levels. Simulated particle fluence spectra evidence that the effect of the Be exit window, often included in the X-ray tube design as a first filter and different additional thicknesses of Al and Cu filters can be effectively used to attenuate low energy photons, often responsible for high dose inhomogeneities in thick samples. To assess the feasibility of using the available X-ray spectra for the irradiation of different samples having thicknesses up to several millimetres, the absorbed dose across the sample’s depth for different materials such as Radio Photoluminescent (RPL) glass dosimeters, silica for comparison purposes and water as reference was calculated using PHITS, with a sample depth spatial resolution of 0.1 mm and 10 µm. The homogeneity of the absorbed dose in the RPL dosimeter volume can be improved by the use of appropriate types of filters and it is found that 1.5 mm, 3 mm thick Al and 1.5 mm thick Cu filters can improve the dose homogeneity to 30 %, 15 %, and 8 % deviation from the average dose value respectively in the selected samples. By using a combination of the readout of PTW soft X-ray ionization chamber, normally used for dose rate calibration in the irradiation facility, and the realized simulations, the absorbed dose was calculated for 8 RPL glass samples irradiated in the MOPERIX X-ray irradiator in the frame of another study. The calculated doses are in good agreement with the corresponding experimental values, which were measured in the European Organization for Nuclear Research (CERN) readout systems, allowing a validation of the used methodologies and the estimation of usable conversion factors.en
dc.format.extent57
dc.language.isoen
dc.rightsIn Copyright
dc.titleDosimetry study in an X-ray irradiator : Monte Carlo simulations and experimental results on radio-photoluminescence samples
dc.typemaster thesis
dc.identifier.urnURN:NBN:fi:jyu-202310025340
dc.type.ontasotMaster’s thesisen
dc.type.ontasotPro gradu -tutkielmafi
dc.contributor.tiedekuntaMatemaattis-luonnontieteellinen tiedekuntafi
dc.contributor.tiedekuntaFaculty of Sciencesen
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.yliopistoJyväskylän yliopistofi
dc.contributor.yliopistoUniversity of Jyväskyläen
dc.contributor.oppiaineFysiikkafi
dc.contributor.oppiainePhysicsen
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.rights.copyright© The Author(s)
dc.rights.accesslevelopenAccess
dc.type.publicationmasterThesis
dc.contributor.oppiainekoodi4021
dc.subject.ysosäteilyannokset
dc.subject.ysosimulointi
dc.subject.ysosäteily
dc.subject.ysodosimetrit
dc.subject.ysoröntgensäteily
dc.subject.ysofotonit
dc.subject.ysosäteilyfysiikka
dc.subject.ysoMonte Carlo -menetelmät
dc.subject.ysoionisoiva säteily
dc.subject.ysoradiation doses
dc.subject.ysosimulation
dc.subject.ysoradiation
dc.subject.ysodosimeters
dc.subject.ysoX-ray radiation
dc.subject.ysophotons
dc.subject.ysoradiation physics
dc.subject.ysoMonte Carlo methods
dc.subject.ysoionising radiation
dc.rights.urlhttps://rightsstatements.org/page/InC/1.0/


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

In Copyright
Ellei muuten mainita, aineiston lisenssi on In Copyright