ECRIS plasma spectroscopy with a high resolution spectrometer
Kronholm, R., Kalvas, T., Koivisto, H., Kosonen, S., Marttinen, M., Neben, D., Sakildien, M., Tarvainen, O., & Toivanen, V. (2020). ECRIS plasma spectroscopy with a high resolution spectrometer. Review of Scientific Instruments, 91(1), Article 013318. https://doi.org/10.1063/1.5128854
Published in
Review of Scientific InstrumentsAuthors
Date
2020Copyright
© 2020 Author(s)
Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction voltage of the ion source is switched off, accompanied by two orders of magnitude decrease in Ar9+ optical emission intensity, suggesting that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions of normal ECRIS operation. The relative changes of the plasma optical emission and the ion beam current have been measured in CW and amplitude modulation operation mode of microwave injection. It is concluded that in the CW mode, the ion currents could be limited by diffusion transport and electrostatic confinement of the ions rather than beam formation in the extraction region and subsequent transport. The high resolution of the spectrometer allows determining the ion temperature by measuring the Doppler broadening of the emission lines and subtracting the wavelength dependent instrumental broadening. The measured ion temperatures in the JYFL 14 GHz ECRIS are between 5 and 28 eV, depending on the plasma species and charge state. Gas mixing is shown to be an effective method to decrease the ion temperature of high charge state argon ions from 20 eV in pure argon discharge to 5 eV when mixed with oxygen.
I. INTR
...
Publisher
American Institute of PhysicsISSN Search the Publication Forum
0034-6748Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/34187675
Metadata
Show full item recordCollections
Related funder(s)
Research Council of Finland; European CommissionFunding program(s)
Academy Project, AoF; Research infrastructures, H2020
The content of the publication reflects only the author’s view. The funder is not responsible for any use that may be made of the information it contains.
Additional information about funding
The JYFL high resolution spectroscopy project has received funding from the European Union’s Horizon 2020 research and innovation programme under Grant Agreement No. 654002 and the Academy of Finland under the Finnish Centre of Excellence Programme 2012–2017 (Nuclear and Accelerator Based Physics Research at JYFL, Project No. 213503) and the Academy of Finland Project funding (No. 315855).License
Related items
Showing items with similar title or keywords.
-
Electron spectroscopy with the SAGE spectrometer
Sorri, Juha (University of Jyväskylä, 2016)A device called the SAGE (Silicon And GErmanium) spectrometer, designed for in-beam electron spectroscopy, is introduced in this work. A detailed description to the technical aspects of the device is given along with ... -
The effect of microwave power on the Ar9+ and Ar13+ optical emission intensities and ion beam currents in ECRIS
Kronholm, Risto; Sakildien, M.; Neben, D.; Koivisto, Hannu; Kalvas, Taneli; Tarvainen, Olli; Laulainen, J.; Jones, P. (AIP Publishing, 2018)The production of Ar9+ and Ar13+ ions in an ECRIS plasma and the efficiency of the ion beam extraction and transport of the resulting Ar9+ and Ar13+ ion beams have been studied with the JYFL 14 GHz ECRIS by using optical ... -
First demonstration of Doppler-free 2-photon in-source laser spectroscopy at the ISOLDE-RILIS
Chrysalidis, K.; Wilkins, S. G.; Heinke, R.; Koszorus, A.; de Groote, Ruben; Fedosseev, V. N.; Marsh, B.; Rothe, S.; Ruiz, R. Garcia; Studer, D.; Vernon, A.; Wendt, K. (Elsevier BV, 2020) -
A study of VUV emission and the extracted electron-ion ratio in hydrogen and deuterium plasmas of a filament-driven H−/D− ion source
Komppula, J.; Tarvainen, O.; Kalvas, T.; Koivisto, H.; Myllyperkiö, P.; Toivanen, V. (AIP Publishing LLC, 2019)Vacuum ultraviolet (VUV) emission diagnostics for studying differences of electron impact processes in hydrogen and deuterium plasmas are presented. The method is applied to study a filament driven multicusp arc discharge ... -
Plasma response to amplitude modulation of the microwave power on a 14 GHz electron cyclotron resonance ion source
Neben, Derek; Tarvainen, Olli; Kronholm, Risto; Koivisto, Hannu; Kalvas, Taneli; Machicoane, Guillaume; Leitner, Daniela (AIP Publishing, 2018)This paper reports the effects of sinusoidal microwave power Amplitude Modulation (AM) on the performance of Electron Cyclotron Resonance (ECR) ion sources. The study was conducted on the 14 GHz ECR ion source ECR2 at the ...