dc.contributor.author | Haapala, Eero | |
dc.contributor.author | Veijalainen, Aapo | |
dc.contributor.author | Kujala, Urho | |
dc.contributor.author | Finni Juutinen, Taija | |
dc.date.accessioned | 2018-12-04T07:53:10Z | |
dc.date.available | 2019-06-03T21:35:17Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Haapala, E., Veijalainen, A., Kujala, U., & Finni Juutinen, T. (2019). Reproducibility of pulse wave velocity and augmentation index derived from non-invasive occlusive oscillometric tonometry analysis in adolescents. <i>Clinical Physiology and Functional Imaging</i>, <i>39</i>(1), 22-28. <a href="https://doi.org/10.1111/cpf.12528" target="_blank">https://doi.org/10.1111/cpf.12528</a> | |
dc.identifier.other | CONVID_28095296 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/60455 | |
dc.description.abstract | The aim of this study was to investigate the short‐term reproducibility of aortic pulse wave velocity (PWVao) and augmentation index (AIx%) assessed by the non‐invasive oscillometric device. Altogether of 55 (19 boys, 36 girls) adolescents 16–19‐years‐of‐age participated in the study. PWVao and AIx% were measured during the same laboratory visit at 2 min intervals using the Arteriograph™ device. Peak oxygen uptake (V̇O2peak) was assessed by the maximal exercise test on a cycle ergometer and body fat percentage by bioelectrical impedance analysis. We studied reproducibility using intraclass correlation coefficients (ICC), coefficient variation with the root‐means‐square method expressed as percentages (CV%), and 95% limit of agreement (95% LA) and coefficient repeatability of the Bland‐Altman plot. ICC for PWVao was 0·90, CV% 3·7 and the limits of agreement were −0·70 and 0·58 with a coefficient repeatability of 0·65. ICC for AIx% was 0·88, CV% 29·1%, and the limits of agreement were −6·8 and 7·1 with a coefficient repeatability of 6·9. No relevant differences in ICC, CV%, and coefficient repeatability for PWVao between adolescents with higher or lower V̇O2peak or body fat percentage were observed. For AIx%, ICC was lower, CV% higher and coefficient repeatability higher in adolescents with higher V̇O2peak or lower body fat percentage than in adolescents with lower V̇O2peak or higher body fat percentage. Short‐term reproducibility of Arteriograph™‐derived PWVao was relatively good and was not affected by V̇O2peak or adiposity. However, the reproducibility of AIx% was modest especially among adolescents with higher V̇O2peak and lower body fat percentage. | fi |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell Publishing Ltd.; Scandinavian Society of Clinical Physiology and Nuclear Medicine | |
dc.relation.ispartofseries | Clinical Physiology and Functional Imaging | |
dc.rights | In Copyright | |
dc.subject.other | adiposity | |
dc.subject.other | arterial stiffness | |
dc.subject.other | fitness | |
dc.subject.other | reliability | |
dc.title | Reproducibility of pulse wave velocity and augmentation index derived from non-invasive occlusive oscillometric tonometry analysis in adolescents | |
dc.type | research article | |
dc.identifier.urn | URN:NBN:fi:jyu-201812034979 | |
dc.contributor.laitos | Liikuntatieteellinen tiedekunta | fi |
dc.contributor.laitos | Faculty of Sport and Health Sciences | en |
dc.contributor.oppiaine | Biomekaniikka | fi |
dc.contributor.oppiaine | Liikuntalääketiede | fi |
dc.contributor.oppiaine | Biomechanics | en |
dc.contributor.oppiaine | Sports and Exercise Medicine | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.date.updated | 2018-12-03T10:15:27Z | |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.description.reviewstatus | peerReviewed | |
dc.format.pagerange | 22-28 | |
dc.relation.issn | 1475-0961 | |
dc.relation.numberinseries | 1 | |
dc.relation.volume | 39 | |
dc.type.version | acceptedVersion | |
dc.rights.copyright | © 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd. | |
dc.rights.accesslevel | openAccess | fi |
dc.type.publication | article | |
dc.subject.yso | verenkierto | |
dc.subject.yso | fyysinen kunto | |
dc.subject.yso | maksimaalinen hapenotto | |
dc.subject.yso | kehonkoostumus | |
dc.subject.yso | rasvaprosentti | |
dc.subject.yso | nuoret | |
dc.subject.yso | nuoruus | |
dc.format.content | fulltext | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p16243 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p7384 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p25454 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p26989 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p25528 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p11617 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p15327 | |
dc.rights.url | http://rightsstatements.org/page/InC/1.0/?language=en | |
dc.relation.doi | 10.1111/cpf.12528 | |
dc.type.okm | A1 | |