A novel method was developed for studying the ink-paper interface and the structural variations of
a deposited layer of ink. Combining high-resolution x-ray tomography with laser ablation, the
depth profile of ink (toner), i.e., its varying thickness, could be determined in a paper substrate.
X-ray tomography was used to produce the 3D structure of paper with about 1 lm spatial resolution.
Laser ablation combined with optical imaging was used to produce the 3D structure of the
printed layer of ink on top of that paper with about 70 nm depth resolution. Ablation depth was calibrated
with an optical profilometer. It can be concluded that a toner layer on a light-weight-coated
paper substrate was strongly perturbed by protruding fibers of the base paper. Such fibers together
with the surface topography of the base paper seem to be the major factors that control the leveling
of toner and its penetration into a thinly coated paper substrate.
Julkaisija
American Institute of PhysicsISSN Hae Julkaisufoorumista
0021-8979Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/24689101
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Predicting stiffness and strength of birch pulp : polylactic acid composites
Sippola, Merja; Immonen, Kirsi; Miettinen, Arttu; Laukkanen, Anssi; Andesson, Tom; Peltola, Heidi; Harlin, Ali; Holmberg, Kenneth (Sage Publications Ltd., 2016)This paper studies failure of birch pulp–polylactic acid composites. Stiffness and strength are calculated using the theory of short fibre composites and the results are compared to experimental data. The results differed ... -
Cluster priors in the Bayesian modelling of fMRI data
Taskinen, Ilkka (University of Jyväskylä, 2001) -
Simple Muscle Architecture Analysis (SMA) : An ImageJ macro tool to automate measurements in B-mode ultrasound scans
Seynnes, Oliver R.; Cronin, Neil J. (Public Library of Science, 2020)In vivo measurements of muscle architecture (i.e. the spatial arrangement of muscle fascicles) are routinely included in research and clinical settings to monitor muscle structure, function and plasticity. However, in most ... -
SLMotion – An extensible sign language oriented video analysis tool
Karppa, Matti; Viitaniemi, Ville; Luzardo, Marcos; Laaksonen, Jorma; Jantunen, Tommi (European Language Resources Association (LREC), 2014)We present a software toolkit called SLMotion which provides a framework for automatic and semiautomatic analysis, feature extraction and annotation of individual sign language videos, and which can easily be adapted to ... -
S-pot – a benchmark in spotting signs within continuous signing
Viitaniemi, Ville; Jantunen, Tommi; Savolainen, Leena; Karppa, Matti; Laaksonen, Jorma (European Language Resources Association (LREC), 2014)In this paper we present S-pot, a benchmark setting for evaluating the performance of automatic spotting of signs in continuous sign language videos. The benchmark includes 5539 video files of Finnish Sign Language, ground ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.