Näytä suppeat kuvailutiedot

dc.contributor.authorMiettinen, Arttu
dc.contributor.authorEkman, Axel
dc.contributor.authorChinga-Carrasco, Gary
dc.contributor.authorKataja, Markku
dc.date.accessioned2015-08-18T05:47:22Z
dc.date.available2016-07-17T21:45:05Z
dc.date.issued2015
dc.identifier.citationMiettinen, A., Ekman, A., Chinga-Carrasco, G., & Kataja, M. (2015). Measuring intrinsic thickness of rough membranes: application to nanofibrillated cellulose films. <i>Journal of Materials Science</i>, <i>50</i>(21), 6926-6934. <a href="https://doi.org/10.1007/s10853-015-9243-2" target="_blank">https://doi.org/10.1007/s10853-015-9243-2</a>
dc.identifier.otherCONVID_24797952
dc.identifier.otherTUTKAID_66628
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/46639
dc.description.abstractAdequate measurement of thickness of sheet-like materials or membranes is most important for quantifying their properties such as density, barrier properties and mechanical strength. Depending on the surface roughness of the membrane, the thickness measured by standard micrometre devices (apparent thickness) may considerably overestimate the actual geometrical mean thickness (intrinsic thickness) required for such purposes. In this work, we present a method for correcting the measured apparent thickness value of thin membranes for their surface roughness, thereby obtaining an improved estimate of the intrinsic thickness. The surface roughness data required for the correction can be obtained by common surface profiling techniques. The method includes a calibration parameter, the value of which can be found experimentally by independent measurements, or can be estimated theoretically using results from standard mechanical contact theory. The method is tested on a set of nanofibrillated cellulose films with varying roughness levels controlled by pulp fibre content. The surface topography of film samples was measured using laser profilometry, and the method was calibrated experimentally using data from X-ray microtomographic images for one type of film. The intrinsic thickness estimates given by the new method are generally in good accordance with independent results obtained from X-ray microtomography.
dc.language.isoeng
dc.publisherSpringer US
dc.relation.ispartofseriesJournal of Materials Science
dc.subject.otherintrinsic thickness
dc.subject.othernanofibrillated cellulose films
dc.titleMeasuring intrinsic thickness of rough membranes: application to nanofibrillated cellulose films
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-201508172687
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.oppiaineFysiikkafi
dc.contributor.oppiainePhysicsen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2015-08-17T15:15:11Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange6926-6934
dc.relation.issn0022-2461
dc.relation.numberinseries21
dc.relation.volume50
dc.type.versionacceptedVersion
dc.rights.copyright© Springer Science+Business Media New York 2015. This is a final draft version of an article whose final and definitive form has been published by Springer. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.subject.ysokalvot (biologia)
dc.subject.ysopaksuus
jyx.subject.urihttp://www.yso.fi/onto/yso/p21156
jyx.subject.urihttp://www.yso.fi/onto/yso/p21144
dc.relation.doi10.1007/s10853-015-9243-2
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot