Näytä suppeat kuvailutiedot

dc.contributor.authorSorri, Juha
dc.contributor.authorGreenlees, Paul
dc.contributor.authorPapadakis, Philippos
dc.contributor.authorKonki, Joonas
dc.contributor.authorCox, Daniel
dc.contributor.authorAuranen, Kalle
dc.contributor.authorPartanen, Jari
dc.contributor.authorSandzelius, Mikael
dc.contributor.authorPakarinen, Janne
dc.contributor.authorRahkila, Panu
dc.contributor.authorUusitalo, Juha
dc.contributor.authorHerzberg, R.-D.
dc.contributor.authorSmallcombe, J.
dc.contributor.authorDavies, P.J.
dc.contributor.authorBarton, C.J.
dc.contributor.authorJenkins, D.G.
dc.date.accessioned2016-06-29T06:11:50Z
dc.date.available2017-12-30T22:45:10Z
dc.date.issued2016
dc.identifier.citationSorri, J., Greenlees, P., Papadakis, P., Konki, J., Cox, D., Auranen, K., Partanen, J., Sandzelius, M., Pakarinen, J., Rahkila, P., Uusitalo, J., Herzberg, R.-D., Smallcombe, J., Davies, P.J., Barton, C.J., & Jenkins, D.G. (2016). Determination of absolute internal conversion coefficients using the SAGE spectrometer. <i>Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment</i>, <i>812</i>, 24-32. <a href="https://doi.org/10.1016/j.nima.2015.12.041" target="_blank">https://doi.org/10.1016/j.nima.2015.12.041</a>
dc.identifier.otherCONVID_25456031
dc.identifier.otherTUTKAID_68680
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/50626
dc.description.abstractA non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of 154Sm, 152Sm and 166Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofseriesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
dc.subject.otherelectron spectroscopy
dc.subject.otherbackground subtraction
dc.subject.otherenergy reconstruction
dc.subject.otherinternal conversion coefficient
dc.subject.othersilicon detector
dc.titleDetermination of absolute internal conversion coefficients using the SAGE spectrometer
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-201606283370
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.oppiaineFysiikkafi
dc.contributor.oppiaineKiihdytinlaboratoriofi
dc.contributor.oppiainePhysicsen
dc.contributor.oppiaineAccelerator Laboratoryen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2016-06-28T12:15:09Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange24-32
dc.relation.issn0168-9002
dc.relation.numberinseries0
dc.relation.volume812
dc.type.versionacceptedVersion
dc.rights.copyright© 2016 Elsevier B.V. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.relation.doi10.1016/j.nima.2015.12.041
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot