Lung counting with a highly segmented HPGe detector
Jutila, H., Greenlees, P., Rahkila, P., Torvela, T., & Muikku, M. (2024). Lung counting with a highly segmented HPGe detector. Applied Radiation and Isotopes, 212, Article 111452. https://doi.org/10.1016/j.apradiso.2024.111452
Julkaistu sarjassa
Applied Radiation and IsotopesPäivämäärä
2024Tekijänoikeudet
© 2024 the Authors
A highly segmented High-Purity Germanium (HPGe) detector was used to measure 241Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.
Julkaisija
ElsevierISSN Hae Julkaisufoorumista
0969-8043Asiasanat
Julkaisuun liittyvä(t) tutkimusaineisto(t)
https://doi.org/10.23729/605138df-3bf9-4e5b-8671-5015de5d8ee8Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/233286198
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Improving the detection limit in lung counting with a segmented HPGe detector
Jutila, Henri; Greenlees, Paul; Torvela, Tiina; Muikku, Maarit (Elsevier, 2024)A segmented High-Purity Germanium (HPGe) detector with a thin front segment together with various active and passive shield configurations was simulated with the aim of reducing the level of background events in lung ... -
Technical note : Simulation of lung counting applications using Geant4
Jutila, Henri; Greenlees, Paul; Torvela, Tiina; Muikku, Maarit (Elsevier, 2023)A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a ... -
Low-Dose Mouse Micro-CT Image Segmentation Based on Multi-Resolution Multi-Organ Shape Prior Knowledge Model
Chen, Zhonghua; Wang, Hongkai; Cong, Fengyu; Kettunen, Lauri (IEEE, 2022)Automatic segmentation of computed tomography (CT) images of mice is a step toward computer-assisted preclinical image analysis. Due to the low image quality of micro-CT images, fully-automatic methods may not achieve ... -
Tracer migration in crystalline rock : application to geological barriers of nuclear waste storage
Kuva, Jukka (University of Jyväskylä, 2016)This work deals with transport of radionuclides in the geosphere. The subject is investigated through characterisation of water conducting fractures, determining of rock transport properties and development of new methods ... -
Nuclear Data and Experiments for Astrophysics
Kankainen, Anu; Goriely, Stephane (Springer International Publishing, 2022)Nuclear astrophysics aims to understand the origin of elements and the role of nuclear processes in astrophysical events. Nuclear reactions and reaction rates depend strongly on nuclear properties and on the astrophysical ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.