Objective
Diseases affecting sensorimotor function impair physical independence. Reliable functional clinical biomarkers allowing early diagnosis or targeting treatment and rehabilitation could reduce this burden. Magnetoencephalography (MEG) non-invasively measures brain rhythms such as the somatomotor ‘rolandic’ rhythm which shows intermittent high-amplitude beta (14-30Hz) ‘events’ that predict behavior across tasks and species and are altered by sensorimotor neurological diseases.
Methods
We assessed test-retest stability, a prerequisite for biomarkers, of spontaneous sensorimotor aperiodic (1/f) signal and beta events in 50 healthy human controls across two MEG sessions using the intraclass correlation coefficient (ICC). Beta events were determined using an amplitude-thresholding approach on a narrow-band filtered amplitude envelope obtained using Morlet wavelet decomposition.
Results
Resting sensorimotor characteristics showed good to excellent test-retest stability. Aperiodic component (ICC 0.77-0.88) and beta event amplitude (ICC 0.74-0.82) were very stable, whereas beta event duration was more variable (ICC 0.55-0.7). 2-3 minute recordings were sufficient to obtain stable results. Analysis automatization was successful in 86%.
Conclusions
Sensorimotor beta phenotype is a stable feature of an individual’s resting brain activity even for short recordings easily measured in patients.
Significance
Spontaneous sensorimotor beta phenotype has potential as a clinical biomarker of sensorimotor system integrity.
...
Publisher
ElsevierISSN Search the Publication Forum
1388-2457Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/207756778
Metadata
Show full item recordCollections
Additional information about funding
We acknowledge the following funding sources: AP received funding from the Academy of Finland (grant number 350242), the Sigrid Juselius Foundation and the Finnish Medical Foundation. Pietari Nurmi received funding from the Finnish Cultural Foundation and the Swedish Cultural Foundation in Finland. Heidi Ala-Salomäki received funding from the Jenny and Antti Wihuri foundation and the Finnish Cultural Foundation. HR received funding from the Academy of Finland (grant numbers 127401 and 321460). Mia Liljeström received funding from the Swedish Cultural Foundation in Finland. ...License
Related items
Showing items with similar title or keywords.
-
Human sensorimotor beta event characteristics and aperiodic signal are highly heritable
Pauls, K. Amande M.; Salmela, Elina; Korsun, Olesia; Kujala, Jan; Salmelin, Riitta; Renvall, Hanna (Society for Neuroscience, 2024)Individuals’ phenotypes, including the brain's structure and function, are largely determined by genes and their interplay. The resting brain generates salient rhythmic patterns that can be characterized non-invasively ... -
Test-retest reliability of selected items of Health Behaviour in School-aged Children (HBSC) survey questionnaire in Beijing, China
Liu, Yang; Wang, Mei; Tynjälä, Jorma; Lv, Yan; Villberg, Jari; Zhang, Zhouyang; Kannas, Lasse (BioMed Central (BMC), 2010)Abstract Background Children's health and health behaviour are essential for their development and it is important to obtain abundant and accurate information to understand young people's health and health ... -
Test-retest reliability of survey items on ownership and use of physical activity trackers
Ng, Kwok W.; Badura, Petr; Dzielska, Anna; Kokko, Sami; Woods, Catherine B.; Hamrik, Zdenek (Palacký University Olomouc, 2019)Background: Researchers are interested in using digital tools, such as physical activity trackers (PAT), to promote and measure physical activity. PAT is a fast-growing research area that measures movement therefore, ... -
Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
Tuominen, Juho; Leppänen, Mari; Jarske, Heidi; Pasanen, Kati; Vasankari, Tommi; Parkkari, Jari (MDPI AG, 2023)Background: The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated. Objective: To examine the ... -
Test-retest reliability of motor-evoked potentials at 20% and 60% of maximum isometric voluntary contraction in rectus femoris muscle
Gomez-Guerrero, Gonzalo; Avela, Janne; Enroth, Miro; Häkkinen, Ella; Ansdell, Paul; Howatson, Glyn; Walker, Simon (Elsevier BV, 2023)