dc.contributor.author | Tuominen, Juho | |
dc.contributor.author | Leppänen, Mari | |
dc.contributor.author | Jarske, Heidi | |
dc.contributor.author | Pasanen, Kati | |
dc.contributor.author | Vasankari, Tommi | |
dc.contributor.author | Parkkari, Jari | |
dc.date.accessioned | 2023-03-20T05:40:09Z | |
dc.date.available | 2023-03-20T05:40:09Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | Tuominen, J., Leppänen, M., Jarske, H., Pasanen, K., Vasankari, T., & Parkkari, J. (2023). Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro. <i>Methods and Protocols</i>, <i>6</i>(2), Article 26. <a href="https://doi.org/10.3390/mps6020026" target="_blank">https://doi.org/10.3390/mps6020026</a> | |
dc.identifier.other | CONVID_177369607 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/86030 | |
dc.description.abstract | Background: The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated. Objective: To examine the test−retest reliability of isokinetic ankle plantar and dorsiflexion, ankle inversion and eversion, knee extension and flexion and hip abduction and adduction strength in physically active adults using Biodex System 4 Pro. Methods: Peak torques (PTs) and average peak torques (APTs) of the dominant and nondominant lower limbs were tested twice in 19 physically active adults 7 to 14 days apart. Results: The intraclass correlation coefficients (ICC) values varied from excellent to moderate and coefficient of variation of typical error (CVTE) values were 6.6–19.5%. Change in the mean expressed as a percent varied from −3.1% to 9.6%. There was no difference in the reliability between PT and APT values. Dominant lower limb was more reliable in every case if there was difference between limbs. Conclusion: Test−retest reliability of isokinetic ankle, knee and hip strength in physically active adults using Biodex System 4 is mostly good or excellent. However, the observed range of the random variation has to be noted when using it in scientific follow-up studies or evaluation of patient progress in clinical settings. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | MDPI AG | |
dc.relation.ispartofseries | Methods and Protocols | |
dc.rights | CC BY 4.0 | |
dc.subject.other | isokineettinen dynamometri | |
dc.subject.other | isokinetic | |
dc.subject.other | dynamometry | |
dc.subject.other | Biodex | |
dc.subject.other | test−retest | |
dc.subject.other | reliability | |
dc.subject.other | ankle | |
dc.subject.other | knee | |
dc.subject.other | hip | |
dc.title | Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro | |
dc.type | article | |
dc.identifier.urn | URN:NBN:fi:jyu-202303202182 | |
dc.contributor.laitos | Liikuntatieteellinen tiedekunta | fi |
dc.contributor.laitos | Faculty of Sport and Health Sciences | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.description.reviewstatus | peerReviewed | |
dc.relation.issn | 2409-9279 | |
dc.relation.numberinseries | 2 | |
dc.relation.volume | 6 | |
dc.type.version | publishedVersion | |
dc.rights.copyright | © 2023 by the authors. Licensee MDPI, Basel, Switzerland. | |
dc.rights.accesslevel | openAccess | fi |
dc.subject.yso | lonkka | |
dc.subject.yso | nilkat | |
dc.subject.yso | reliabiliteetti | |
dc.subject.yso | mittauslaitteet | |
dc.subject.yso | polvet | |
dc.subject.yso | lihasvoima | |
dc.subject.yso | mittausmenetelmät | |
dc.format.content | fulltext | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p7232 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p24005 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p9970 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p3583 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p14204 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p23362 | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p20083 | |
dc.rights.url | https://creativecommons.org/licenses/by/4.0/ | |
dc.relation.doi | 10.3390/mps6020026 | |
jyx.fundinginformation | We acknowledge the funding from Finnish Ministry of Education and Culture, and the Competitive State Research Financing of the Expert Responsibility Area of Tampere University Hospital (Grant 9AB055). | |
dc.type.okm | A1 | |