Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels
Gomez-Guerrero, G., Avela, J., Enroth, M., Häkkinen, E., Ansdell, P., Howatson, G., & Walker, S. (2023). Test–retest reliability of cortico-spinal measurements in the rectus femoris at different contraction levels. Frontiers in Neuroscience, 17, Article 1239982. https://doi.org/10.3389/fnins.2023.1239982
Published in
Frontiers in NeuroscienceAuthors
Date
2023Discipline
ResurssiviisausyhteisöBiomekaniikkaHyvinvoinnin tutkimuksen yhteisöSchool of Resource WisdomBiomechanicsSchool of WellbeingCopyright
© 2023 Gomez-Guerrero, Avela, Enroth, Häkkinen, Ansdell, Howatson and Walker.
Single-pulse Transcranial Magnetic Stimulation (TMS) and, very recently, lumbar stimulation (LS) have been used to measure cortico-spinal excitability from various interventions using maximal or submaximal contractions in the lower limbs. However, reliability studies have overlooked a wide range of contraction intensities for MEPs, and no reliability data is available for LEPs. This study investigated the reliability of motor evoked potentials and lumbar evoked potentials at different stimulation intensities and contraction levels in m.rectus femoris. Twenty-two participants performed non-fatiguing isometric knee extensions at 20 and 60% of maximum voluntary contraction (MVC). LS induced a lumbar-evoked potential (LEP) of 25 and 50% resting maximal compound action potential (M-max). TMS stimulator output was adjusted to 120, 140, and 160% of active motor threshold (aMT). In each contraction, a single MEP or LEP was delivered. Ten contractions were performed at each stimulator intensity and contraction level in random order. Moderate-to-good reliability was found when LEP was normalized to M-max/ Root Mean Square in all conditions (ICC:0.74–0.85). Excellent reliability was found when MEP was normalized to Mmax for all conditions (ICC > 0.90) at 60% of MVC. Good reliability was found for the rest of the TMS conditions. Moderateto-good reliability was found for silent period (SP) elicited by LS (ICC: 0.71–0.83). Good-to-excellent reliability was found for SP elicited by TMS (ICC > 0.82). MEPs and LEPs elicited in m.rectus femoris appear to be reliable to assess changes at different segments of the cortico-spinal tract during different contraction levels and stimulator output intensities. Furthermore, the TMS- and LS- elicited SP was a reliable tool considered to reflect inhibitory processes at spinal and cortical levels.
...
Publisher
Frontiers Media SAISSN Search the Publication Forum
1662-4548Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/189042933
Metadata
Show full item recordCollections
- Liikuntatieteiden tiedekunta [3214]
License
Related items
Showing items with similar title or keywords.
-
Test-retest reliability of motor-evoked potentials at 20% and 60% of maximum isometric voluntary contraction in rectus femoris muscle
Gomez-Guerrero, Gonzalo; Avela, Janne; Enroth, Miro; Häkkinen, Ella; Ansdell, Paul; Howatson, Glyn; Walker, Simon (Elsevier BV, 2023) -
Reliability of transcranial magnetic stimulation and H-reflex measurement during balance perturbation tasks
Hu, Nijia; Avela, Janne; Kidgell, Dawson J.; Nevanperä, Samuli; Walker, Simon; Piirainen, Jarmo M. (Frontiers Media SA, 2022)Following ankle movement, posterior balance perturbation evokes short- (SLR ∼30–50 ms), medium- (MLR ∼50–60 ms), and long-latency responses (LLR ∼70–90 ms) in soleus muscle before voluntary muscle contraction. Transcranial ... -
Modulations of corticospinal excitability following rapid ankle dorsiflexion in skill- and endurance-trained athletes
Hu, Nijia; Avela, Janne; Kidgell, Dawson J.; Piirainen, Jarmo M.; Walker, Simon (Springer, 2022)Purpose Long-term sports training, such as skill and endurance training, leads to specific neuroplasticity. However, it remains unclear if muscle stretch-induced proprioceptive feedback influences corticospinal ... -
Contraction intensity modulates spinal excitability during transcranial magnetic stimulation-evoked silent period in rectus femoris muscle
Gomez-Guerrero, Gonzalo; Ansdell, Paul; Howatson, Glyn; Avela, Janne; Walker, Simon (Springer, 2023)Purpose Reduced spinal excitability during the transcranial magnetic stimulation (TMS) silent period (SP) has recently been shown to last longer than previously thought in the upper limbs, as assessed via spinal electrical ... -
Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
Tuominen, Juho; Leppänen, Mari; Jarske, Heidi; Pasanen, Kati; Vasankari, Tommi; Parkkari, Jari (MDPI AG, 2023)Background: The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated. Objective: To examine the ...