dc.description.abstractA feasibility study on event-mode data acquisition systems, the alpha–gamma coincidence technique and position-sensitive detectors was conducted in Jyväskylä in the summer of 2007. Based on this study, a measurement device named PANDA (Particles And Non-Destructive Analysis) was designed and built at the Finnish Radiation and Nuclear Safety Authority (STUK). The PANDA device has two complementary measurement positions inside a vacuum chamber. The first measurement position hosts an HPGe detector for gamma and X-rays and a position-sensitive double-sided silicon strip detector (DSSSD) for alpha particles. The samples are analysed in close geometry between the detectors. The data are recorded in event mode and each event is time stamped. The second measurement position is equipped with a prototype silicon drift detector (SDD), which is used to detect conversion electrons and low-energy X-rays. The operation and performance of PANDA is presented via the measurements and analysis of various sample types. These include isolated radioactive particles, swipe samples, air filters and impactor samples. For example, the analysis of a cotton swipe sample containing 10 ng of Pu revealed that the 240Pu/239Pu atom ratio was 0.12 ± 0.03. The reference value given by the IAEA was 0.132. The results were congruent despite the fact that the sample itself was far from ideal. In another case, the alpha–gamma coincidence technique of PANDA was compared with traditional low-background gamma singles spectrometry. This comparison was realized by making long measurements in optimum geometries for a small radioactive particle. The analysis results proved that the alpha–gamma coincidence technique provide an approximately six times lower minimum detectable activity for 241Am.en
dc.language.isoeng
dc.relation.ispartofseriesJyväskylän yliopisto. Fysiikan laitos. Research report
dc.relation.haspart<b>Artikkeli I:</b> Peräjärvi, K., Hakala, J., Jokinen, A., Moore, I.D., Penttilä, H., Pöllänen, R., Saastamoinen, A., Toivonen, H., Turunen, J. & Äystö, J. (2009). Event Mode Data Acquisition for Characterization of Samples Containing Radioactive Particles. <i>IEEE Transactions on Nuclear Science 56(3), 1444-1447.</i> DOI: <a href="https://doi.org/10.1109/TNS.2009.2015230"target="_blank"> 10.1109/TNS.2009.2015230</a>
dc.relation.haspart<b>Artikkeli II:</b> Turunen, J., Peräjärvi, K., Pöllänen, R., Toivonen, H. (2010). PANDA – A novel instrument for non-destructive sample analysis. <i>Nuclear Instruments and Methods in Physics Research A, 613, 177-183.</i> DOI: <a href="https://doi.org/10.1016/j.nima.2009.10.099"target="_blank"> 10.1016/j.nima.2009.10.099</a>
dc.relation.haspart<b>Artikkeli III:</b> Turunen, J., Ihantola, S., Peräjärvi, K., Pöllänen, R., Toivonen, H. (2010). Novel spectrometric approach to non-destructive characterization of safeguards samples. <i>ESARDA Bulletin, 45, 23-28.</i>
dc.relation.haspart<b>Artikkeli IV:</b> Peräjärvi, K.A., Ihantola, S., Pöllänen, R.C., Toivonen, H.I., Turunen, J.A. (2011). Determination of 235U, 239Pu, 240Pu, and 241Am in a nuclear bomb particle using a position-sensitive α-γ coincidence technique. <i>Environmental Science and Technology 45 (4), 1528–1533.</i> DOI: <a href="https://doi.org/10.1021/es1033734"target="_blank"> 10.1021/es1033734</a>
dc.relation.haspart<b>Artikkeli V:</b> Turunen, J., Ihantola, S., Peräjärvi, K., Pöllänen, R., Toivonen, H., Hrnecek, E. (2011). Collection and behaviour of radon progenies on thin Mylar foils. <i>Radiation Measurements 46 (6-7), 631-634.</i> DOI: <a href="https://doi.org/10.1016/j.radmeas.2011.04.009"target="_blank"> 10.1016/j.radmeas.2011.04.009</a>
dc.relation.haspart<b>Artikkeli VI:</b> Turunen, J., Ihantola, S., Peräjärvi, K., Toivonen, H. (2012). Comprehensive radioassays of samples using the PANDA device. <i>Nuclear Instruments and Methods in Physics Research A, 678, 78-82.</i> DOI: <a href="https://doi.org/10.1016/j.nima.2012.03.002"target="_blank"> 10.1016/j.nima.2012.03.002</a>
dc.rightsIn Copyright
dc.titleNovel methods for analysis of radioactive samples using position-sensitive detectors, coincidence techniques and event-mode data acquisition
dc.typedoctoral thesis
dc.identifier.urnURN:ISBN:978-951-39-5198-6
dc.contributor.tiedekuntaFaculty of Mathematics and Scienceen
dc.contributor.tiedekuntaMatemaattis-luonnontieteellinen tiedekuntafi
dc.contributor.yliopistoUniversity of Jyväskyläen
dc.contributor.yliopistoJyväskylän yliopistofi
dc.type.coarhttp://purl.org/coar/resource_type/c_db06
dc.relation.issn0075-465X
dc.rights.accesslevelopenAccess
dc.type.publicationdoctoralThesis
dc.rights.urlhttps://rightsstatements.org/page/InC/1.0/


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

In Copyright
Ellei muuten mainita, aineiston lisenssi on In Copyright