A method for measuring wetting and swelling of bentonite using X-ray imaging
Harjupatana, T., Miettinen, A., & Kataja, M. (2022). A method for measuring wetting and swelling of bentonite using X-ray imaging. Applied Clay Science, 221, Article 106485. https://doi.org/10.1016/j.clay.2022.106485
Published in
Applied Clay ScienceDate
2022Copyright
© 2022 The Author(s). Published by Elsevier B.V.
A non-invasive method based on X-ray imaging for measuring deformation and water transport in wetting and swelling bentonite samples is introduced. Sequential X-ray images taken of the samples were used to calculate the attenuation coefficient and deformation. These results, together with careful calibration, allowed finding the dry density and water content distributions and their temporal evolution in the wetting and swelling samples. A specific correction technique, based on regularly taking reference X-ray images of aluminum plates of varying thickness, was developed and used to take into account X-ray beam instabilities and thus to improve the accuracy of density analysis. Large deformation, present in the experiments, was measured with an improved version of a block-matching algorithm. The X-ray imaging method was used here to measure the axial swelling of compacted MX-80 bentonite samples in a tube when in contact with saline solution (0.1 M NaCl). This setup mimics a scenario where bentonite, planned to be used as a buffer material in a nuclear waste repository placed deep in the bedrock, swells into a rock fracture filled by groundwater. The method yielded potentially valuable data on hydro-mechanical behavior of bentonite, which may be used in developing and validating material models to be used in safety assessment of nuclear waste repository concepts.
...
Publisher
ElsevierISSN Search the Publication Forum
0169-1317Keywords
Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/117409177
Metadata
Show full item recordCollections
Additional information about funding
The research leading to these results has received funding from the European Atomic Energy Community's 7th Framework Programme (FP7/2007-2011) under grant agreement no. 295487.License
Related items
Showing items with similar title or keywords.
-
Röntgenkuvantamisesta apua bentoniittipuskurin mallintamiseen
Harjupatana, Tero (Suomen atomiteknillinen seura, 2024)In this dissertation, a method for measuring water transport and deformation in swelling materials was developed. In the method, the wetting of a sample is monitored by taking X-ray or X-ray tomographic images at suitable ... -
X-ray tomographic method for measuring three-dimensional deformation and water content distribution in swelling clays
Harjupatana, Tero; Alaraudanjoki, Jarno; Kataja, Markku (Elsevier BV, 2015)A non-invasive method for simultaneous measurement of the 3D displacement field and the water content distribution of a wetted solid material is developed. The method is based on comparison of X-ray tomographic images of ... -
Monitoring semi-free swelling and water transport in bentonites using X-ray radiography
Tanttu, Joni; Harjupatana, Tero; Miettinen, Arttu; Kataja, Markku (Elsevier, 2024)Clay materials such as montmorillonite-rich bentonite, are planned to be used as buffer materials between waste canisters and host rock in deep geological radioactive waste repositories. To ensure the safety of the repository ... -
Experimental methods for measuring elasto-plastic parameters of bentonite clay
Eloranta, Aaro (2012) -
X-ray tomographic method for measuring 3D deformation and liquid content in swelling materials
Harjupatana, Tero; Alaraudanjoki, Jarno; Kataja, Markku (Rakenteiden mekaniikan seura, 2015)A non-invasive method for measuring the three-dimensional displacement field and liquid content distribution in a wetting and swelling material using X-ray tomographic imaging is introduced. The method is demonstrated ...