Study of radial motion phase advance during motion excitations in a Penning trap and accuracy of JYFLTRAP mass spectrometer
Nesterenko, D. A., Eronen, T., Ge, Z., Kankainen, A., & Vilen, M. (2021). Study of radial motion phase advance during motion excitations in a Penning trap and accuracy of JYFLTRAP mass spectrometer. European Physical Journal A, 57(11), Article 302. https://doi.org/10.1140/epja/s10050-021-00608-3
Published in
European Physical Journal ADate
2021Copyright
© The Author(s) 2021
Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic uncertainties that impose limitations on the accuracy of measurements are discussed. It was found out that the phase evolution of the radial motion of ions in a Penning trap during the application of radio-frequency fields leads to a systematic cyclotron frequency shift when more than one ion species is present in the trap during the cyclotron frequency measurement. An analytic expression was derived to correctly account for the shift. Cross-reference mass measurements with carbon-cluster ions have been performed providing the mass-dependent and residual uncertainties.
Publisher
Springer Science and Business Media LLCISSN Search the Publication Forum
1434-6001Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/102928810
Metadata
Show full item recordCollections
Additional information about funding
Open Access funding provided by University of Jyväskylä (JYU).License
Related items
Showing items with similar title or keywords.
-
Phase-Imaging Ion-Cyclotron-Resonance technique at the JYFLTRAP double Penning trap mass spectrometer
Nesterenko, Dmitrii; Eronen, Tommi; Kankainen, Anu; Canete, Laetitia; Jokinen, Ari; Moore, Iain; Penttilä, Heikki; Rinta-Antila, Sami; de Roubin, Antoine; Vilén, Markus (Springer, 2018)The Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique has been commissioned at the JYFLTRAP double Penning trap mass spectrometer. This technique is based on projecting the ion motion in the Penning trap onto a ... -
Recent experiments at the JYFLTRAP Penning trap
Kankainen, Anu; Eronen, Tommi; Nesterenko, Dmitrii; de Roubin, Antoine; Vilén, Markus (Springer, 2020)The JYFLTRAP double Penning trap mass spectrometer at the Ion Guide Isotope Separator On-Line (IGISOL) facility offers excellent possibilities for high-precision mass measurements of radioactive ions. Around 400 atomic ... -
2021_06_02_TrapOffline: 98Mo-98Ru and 96Ru-96Mo with the JYFLTRAP Penning trap mass spectrometer
Eronen, Tommi; Nesterenko, Dimitrii; Ge, Zhuang; Kankainen, Anu (2022)Data include the measurement data collected with the JYFLTRAP double Penning trap mass spectrometer in the JYFL-ACCLAB Accelerator Laboratory at the University of Jyväskylä and the associated ELOG notes. Supplementary data ... -
An off-line ion guide quadrupole mass spectrometer system
El Youbi, Sara (2017)Off-line ioniohjain kvadrupolimassaspektrometri systeemi. Uuden erillisen ioniohjain-kvadrupolimassaspektrometri (IGQMS) -systeemin käyttöönotto on esitetty tässä työssä. Laitteisto on kehitetty uusien tekniikoiden ... -
High-precision mass measurements of 25Al and 30P at JYFLTRAP
Canete, Laetitia; Kankainen, Anu; Eronen, Tommi; Gorelov, Dmitry; Hakala, Jani; Jokinen, Ari; Kolhinen, Veli; Koponen, Jukka; Moore, Iain; Reinikainen, Juuso; Rinta-Antila, Sami (Springer Berlin Heidelberg, 2016)The masses of the astrophysically relevant nuclei 25Al and 30P have been measured with a Penning trap for the first time. The mass-excess values for 25Al ( Δ=−8915.962(63) keV) and 30P ( Δ=−20200.854(64) keV) obtained with ...