Upgrade of ALICE forward detectors
Slupecki, M. (2019). Upgrade of ALICE forward detectors. In S. Choi, S. Y. Choi, J. E. Kim, Y. Kim, U.-K. Yang, & Y. Kwon (Eds.), ICHEP2018 : Proceedings of The 39th International Conference on High Energy Physics (Article 255). Sissa. POS Proceedings of Science, 340. https://doi.org/10.22323/1.340.0255
Published in
POS Proceedings of ScienceAuthors
Editors
Date
2019Discipline
FysiikkaYdin- ja kiihdytinfysiikan huippuyksikköPhysicsCentre of Excellence in Nuclear and Accelerator Based PhysicsCopyright
© Authors, 2020
ALICE will upgrade its subsystems in 2019−2020 to fully benefit from the increased collision rate and luminosity of the LHC at CERN. Two new forward detectors will be installed at the core of ALICE: the Fast Interaction Trigger (FIT) and the Muon Forward Tracker (MFT). Additionally, during the shutdown between Run 3 and Run 4, there will be an opportunity to install the Forward Calorimeter (FoCal). This paper describes these new forward detectors, their physics justification and goals, selected design features along with performance of detector prototypes and simulated performance figures.
Publisher
SissaConference
The 39th International Conference on High Energy PhysicsIs part of publication
ICHEP2018 : Proceedings of The 39th International Conference on High Energy PhysicsISSN Search the Publication Forum
1824-8039Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/35389126
Metadata
Show full item recordCollections
License
Related items
Showing items with similar title or keywords.
-
The design and sensitivity of JUNO’s scintillator radiopurity pre-detector OSIRIS
JUNO Collaboration (Springer, 2021)The OSIRIS detector is a subsystem of the liquid scintillator filling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO ... -
Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report
DUNE Collaboration (MDPI AG, 2021)The Deep Underground Neutrino Experiment (DUNE) is an international, world-class experiment aimed at exploring fundamental questions about the universe that are at the forefront of astrophysics and particle physics research. ... -
Eos : conceptual design for a demonstrator of hybrid optical detector technology
Anderson, T.; Anderssen, E.; Askins, M.; Bacon, A.J.; Bagdasarian, Z.; Baldoni, A.; Barros, N.; Bartoszek, L.; Bergevin, M.; Bernstein, A.; Blucher, E.; Boissevain, J.; Bonventre, R.; Brown, D.; Callaghan, E.J.; Cowen, D.F.; Dazeley, S.; Diwan, M.; Duce, M.; Fleming, D.; Frankiewicz, K.; Gooding, D.M.; Grant, C.; Juechter, J.; Kaptanoglu, T.; Kim, T.; Klein, J.R.; Kraus, C.; Kroupová, T.; Land, B.; Lebanowski, L.; Lozza, V.; Marino, A.; Mastbaum, A.; Mauger, C.; Mayers, G.; Minock, J.; Naugle, S.; Newcomer, M.; Nikolica, A.; Orebi Gann, G.D.; Pickard, L.; Ren, L.; Rincon, A.; Rowe, N.; Saba, J.; Schoppmann, S.; Sensenig, J.; Smiley, M.; Song, H.; Steiger, H.; Svoboda, R.; Tiras, E.; To, W.H.; Trzaska, W.H.; Van Berg, R.; Veeraraghavan, V.; Wallig, J.; Wendel, G.; Wetstein, M.; Wurm, M.; Yang, G.; Yeh, M.; Zimmerman, E.D. (IOP Publishing, 2023)Eos is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With a fiducial mass of four tons, Eos is ... -
Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter
Aehle, M.; Alme, J.; Arata, C.; Arsene, I.; Bearden, I.; Bodova, T.; Borshchov, V.; Bourrion, O.; Bregant, M.; van den Brink, A.; Buchakchiev, V.; Buhl, A.; Chujo, T.; Dufke, L.; Eikeland, V.; Fasel, M.; Gauger, N.; Gautam, A.; Ghimouz, A.; Goto, Y.; Guernane, R.; Hachiya, T.; Hassan, H.; He, L.; Helstrup, H.; Huhta, L.; Inaba, M.; Inukai, T.; Isidori, T.; Jonas, F.; Kawaguchi, T.; Keidel, R.; Kim, M.H.; Kozhuharov, V.; Kumaoka, T.; Kusch, L.; Loizides, C.; Melikyan, Y.; Miake, Y.; Minafra, N.; Nystrand, J.; Novitzky, N.; Økland, T.; Oyama, K.; Park, H.; Park, J.; Pascal, I.; Peitzmann, T.; Protsenko, M.; Räsänen, S.S.; Rarbi, F.; Rauch, M.; Rehman, A.; Richter, M.; Röhrich, D.; Røed, K.; Rusu, A.; Rytkönen, H.; Sakai, S.; Sato, K.; Schilling, A.; Shimizu, S.; Shimomura, M.; Simeonov, R.; Solheim, E.; Sugitate, T.; Tambave, G.; Tapia Takaki, D.; Tourres, D.; Tymchuk, I.; Yi, J.; Yin, Z.; Ullaland, K.; Yang, S.; Yokoo, T.; Zhou, D.; Zillien, S. (IOP Publishing, 2024)We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation ... -
Upgrade of OSIRIS for Future Liquid Scintillator Studies
Loo, Kai K. (Sissa, 2024)Understanding the internal radioactive background contributions in its 20 kiloton liquid scintillator (LS) target is essential for the success of the JUNO reactor neutrino experiment. OSIRIS is a 20-tonne radiopurity ...