Tarvainen, O., Kalvas, T., Koivisto, H., Kronholm, R., Marttinen, M., Sakildien, M., Toivanen, V., Izotov, I., Skalyga, V., & Angot, J. (2019). Plasma diagnostic tools for ECR ion sources : What can we learn from these experiments for the next generation sources. Review of Scientific Instruments, 90(11), Article 113321. https://doi.org/10.1063/1.5127050
Julkaistu sarjassa
Review of Scientific InstrumentsTekijät
Päivämäärä
2019Tekijänoikeudet
© 2019 Authors
The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-generation sources operating at frequencies from 10 to 18 GHz. The development of minimum-B ECR ion sources based on the superposition of solenoid and sextupole fields has long relied on semiempirical scaling laws for the strength of the magnetic field with increasing plasma heating frequency. This approach is becoming increasingly difficult with the looming limits of superconducting technologies being able to satisfy the magnetic field requirements at frequencies approaching 60 GHz. Thus, we discuss alternative ECRIS concepts and proposed modifications to existing sources that are supported by the current understanding derived from the plasma diagnostics experiments.
...
Julkaisija
American Institute of PhysicsISSN Hae Julkaisufoorumista
0034-6748Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/33627822
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Rahoittaja(t)
Suomen Akatemia; Euroopan komissioRahoitusohjelmat(t)
Akatemiahanke, SA; Research infrastructures, H2020
The content of the publication reflects only the author’s view. The funder is not responsible for any use that may be made of the information it contains.
Lisätietoja rahoituksesta
This work has received funding from the European Union’s Horizon 2020 research and innovation program under Grant Agreement No. 654002, the Academy of Finland under the Finnish Centre of Excellence Program 2012–2017 (Nuclear and Accelerator Based Physics Research at JYFL, Project No. 213503), and the Academy of Finland Project Funding (No. 315855). The research of V. A. Skalyga and I. V. Izotov was carried out within the state assignment of the Ministry of Science and Higher Education of the Russian Federation No. 0035-2019-0002. ...Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Quasi-periodical kinetic instabilities in minimum-B confined plasma
Bhaskar, B. S.; Koivisto, H.; Tarvainen, O.; Thuillier, T.; Toivanen, V. (AIP Publishing, 2022)We present the results of an experimental investigation of quasi-periodical kinetic instabilities exhibited by magnetically confined electron cyclotron resonance heated plasmas. The instabilities were detected by measuring ... -
Influence of axial mirror ratios on the kinetic instability threshold in electron cyclotron resonance ion source plasma
Toivanen, V.; Bhaskar, B. S.; Koivisto, H.; Maunoury, L.; Tarvainen, O.; Thuillier, T. (American Institute of Physics, 2022)Electron Cyclotron Resonance (ECR) ion source plasmas are prone to kinetic instabilities. The onset of the instabilities manifests as emission of microwaves, bursts of electrons expelled from the plasma volume, and the ... -
Characteristic Kα emission of electron cyclotron resonance ion source plasmas
Sakieldien, Moenir (University of Jyväskylä, 2018)This thesis presents the results of an investigation of the volumetric Kα emission rate/inner shell ionization rate from an Electron Cyclotron Resonance Ion Source (ECRIS) plasma tuned predominantly for high charge state ... -
Bremsstrahlung Emission of an X-Band Permanent Magnet Minimum-B Quadrupole Electron Cyclotron Resonance Ion Source
Tarvainen, Olli; Toivanen, Ville; Kalvas, Taneli; Koivisto, Hannu A.; Kosonen, Sami (Institute of Electrical and Electronics Engineers (IEEE), 2024)We have carried out bremsstrahlung measurements on a permanent magnet minimum-B quadrupole electron cyclotron resonance (ECR) ion source operating at 10.3–11.5 GHz microwave frequencies. The bremsstrahlung spectral temperature ... -
Measurement of ionization, charge exchange and ion confinement times in charge breeder ECR ion sources with short pulse 1+ injection of metal ions
Luntinen, Miha; Angot, Julien; Tarvainen, Olli; Toivanen, Ville; Thuillier, Thomas; Koivisto, Hannu (IOP Publishing, 2022)The Consecutive Transients (CT) method is used for estimating the characteristic times of ionization, charge exchange and confinement within the plasma of a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.