Training Load and Energy Expenditure during Military Basic Training Period
Jurvelin, H., Tanskanen-Tervo, M., Kinnunen, H., Santtila, M., & Kyröläinen, H. (2020). Training Load and Energy Expenditure during Military Basic Training Period. Medicine and Science in Sports and Exercise, 52(1), 86-93. https://doi.org/10.1249/MSS.0000000000002092
Julkaistu sarjassa
Medicine and Science in Sports and ExerciseTekijät
Päivämäärä
2020Tekijänoikeudet
© 2019 American College of Sports Medicine
Purpose: To compare training load and energy expenditure during an 8-week military BT period among individuals having different fitness level using objective measurements in an authentic environment.
Methods: Thirty-four voluntary male conscripts (age 19.1±0.3 years) were divided into three training groups (inactive, moderate, active) by their reported physical activity (PA) level evaluated by the International Physical Activity Questionnaire (IPAQ) prior to military service. Maximal oxygen uptake (VO2max) and heart rate (HR) were determined by maximal treadmill test in the beginning and after 4 and 7 weeks of BT. During BT, HR monitors and accelerometers were used to measure PA and energy expenditure. HR data were used to calculate the training load (TRIMP, training impulse) for each day, week and the whole BT period.
Results: Training load of BT was comparable to training of competitive athletes at the highest level. The training groups differed (p<0.001-0.05) in terms of VO2max to each other (inactive 36±6, moderate 42±6, active 48±6 ml/kg/min). The conscripts in the inactive group were the most loaded during the study period (TRIMPinactive 12393±2989 vs. TRIMPmoderate 10252±1337, p<0.05 and TRIMPactive 8444±2051, p<0.01). The PA intensity of different military tasks during the BT period were low or moderate (<6MET).
Conclusion: The remarkable training load during BT period is comparable to the training loads of professional athletes participating three weeks’ cycling competition. The training load in basic training period was, however, primary due to duration of low intensity activities including only some high intensity military activities. In the future, measuring the training load during the military service is recommended in order to customize the physical training for conscripts regarding his/her fitness level as much as possible.
...
Julkaisija
Lippincott Williams & WilkinsISSN Hae Julkaisufoorumista
0195-9131Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/32265403
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Liikuntatieteiden tiedekunta [3164]
Lisätietoja rahoituksesta
The study was granted by the Finnish Ministry of Education, Finnish Cultural Foundation, Polar Electro Oy and the Scientific Advisory Board for Defence.Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Validity of three smartwatches in estimating energy expenditure during outdoor walking and running
Le, Shenglong; Wang, Xiuqiang; Zhang, Tao; Lei, Si Man; Cheng, Sulin; Yao, Wu; Schumann, Moritz (Frontiers Media SA, 2022)Commercially wrist-worn devices often present inaccurate estimations of energy expenditure (EE), with large between-device differences. We aimed to assess the validity of the Apple Watch Series 6 (AW), Garmin FENIX 6 (GF) ... -
A nonlinear mixed model approach to predict energy expenditure from heart rate
Kortelainen, Lauri; Helske, Jouni; Finni, Taija; Mehtätalo, Lauri; Tikkanen, Olli; Kärkkäinen, Salme (Institute of Physics, 2021)Objective: Heart rate (HR) monitoring provides a convenient and inexpensive way to predict energy expenditure (EE) during physical activity. However, there is a lot of variation among individuals in the EE-HR relationship, ... -
Training-induced changes in daily energy expenditure : Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
Kinnunen, Hannu; Häkkinen, Keijo; Schumann, Moritz; Karavirta, Laura; Westerterp, Klaas R.; Kyröläinen, Heikki (Public Library of Science, 2019)Introduction: Wrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily ... -
Factors contributing to the imbalance between energy intake-energy expenditure in obese Finnish women
Lendewig, Claudia (2011) -
Recommendations for Determining the Validity of Consumer Wearables and Smartphones for the Estimation of Energy Expenditure : Expert Statement and Checklist of the INTERLIVE Network
Argent, Rob; Hetherington-Rauth, Megan; Stang, Julie; Tarp, Jakob; Ortega, Francisco B.; Molina-Garcia, Pablo; Schumann, Moritz; Bloch, Wilhelm; Cheng, Sulin; Grøntved, Anders; Brønd, Jan Christian; Ekelund, Ulf; Sardinha, Luis B.; Caulfield, Brian (Springer Science and Business Media LLC, 2022)Background Consumer wearables and smartphone devices commonly offer an estimate of energy expenditure (EE) to assist in the objective monitoring of physical activity to the general population. Alongside consumers, healthcare ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.