Training-induced changes in daily energy expenditure : Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique
Kinnunen, H., Häkkinen, K., Schumann, M., Karavirta, L., Westerterp, K. R., & Kyröläinen, H. (2019). Training-induced changes in daily energy expenditure : Methodological evaluation using wrist-worn accelerometer, heart rate monitor, and doubly labeled water technique. PLoS ONE, 14(7), Article e0219563. https://doi.org/10.1371/journal.pone.0219563
Julkaistu sarjassa
PLoS ONETekijät
Päivämäärä
2019Oppiaine
Gerontologian tutkimuskeskusHyvinvoinnin tutkimuksen yhteisöGerontology Research CenterSchool of WellbeingTekijänoikeudet
© 2019 Kinnunen et al.
Introduction: Wrist-mounted motion sensors can quantify the volume and intensity of physical activities, but little is known about their long-term validity. Our aim was to validate a wrist motion sensor in estimating daily energy expenditure, including any change induced by long-term participation in endurance and strength training. Supplemental heart rate monitoring during weekly exercise was also investigated.
Methods: A 13-day doubly labeled water (DLW) measurement of total energy expenditure (TEE) was performed twice in healthy male subjects: during two last weeks of a 12-week Control period (n = 15) and during two last weeks of a 12-week combined strength and aerobic Training period (n = 13). Resting energy expenditure was estimated using two equations: one with body weight and age, and another one with fat-free mass. TEE and activity induced energy expenditure (AEE) were determined from motion sensor alone, and from motions sensor combined with heart rate monitor, the latter being worn during exercise only.
Results: When body weight and age were used in the calculation of resting energy expenditure, the motion sensor data alone explained 78% and 62% of the variation in TEE assessed by DLW at the end of Control and Training periods, respectively, with a bias of +1.75 (p <.001) and +1.19 MJ/day (p = .002). When exercise heart rate data was added to the model, the combined wearable device approach explained 85% and 70% of the variation in TEE assessed by DLW with a bias of +1.89 and +1.75 MJ/day (p <.001 for both). While significant increases in TEE and AEE were detected by all methods as a result of participation in regular training, motion sensor approach underestimated the change measured by DLW: +1.13±0.66 by DLW, +0.59±0.69 (p = .004) by motion sensor, and +0.98±0.70 MJ/day by combination of motion sensor and heart rate. Use of fat-free mass in the estimation of resting energy expenditure removed the biases between the wearable device estimations and the golden standard reference method of TEE and demonstrated a training-induced increase in resting energy expenditure by +0.18±0.13 MJ/day (p <.001).
Conclusions: Wrist motion sensor combined with a heart rate monitor during exercise sessions, showed high agreement with the golden standard measurement of daily TEE and its change induced by participation in a long-term training protocol. The positive findings concerning the validity, especially the ability to follow-up the change associated with a lifestyle modification, can be considered significant because they partially determine the feasibility of wearable devices as quantifiers of health-related behavior.
...
Julkaisija
Public Library of ScienceISSN Hae Julkaisufoorumista
1932-6203Asiasanat
Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/32118629
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Liikuntatieteiden tiedekunta [3139]
Lisätietoja rahoituksesta
This study was supported by grants from the Finnish Ministry of Education and Culture, and Polar Electro.Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
The effects of physical activity and diet change on intracellular lipids and metabolism in mice with diet-induced obesity
Rinnankoski-Tuikka, Rita (University of Jyväskylä, 2014) -
A nonlinear mixed model approach to predict energy expenditure from heart rate
Kortelainen, Lauri; Helske, Jouni; Finni, Taija; Mehtätalo, Lauri; Tikkanen, Olli; Kärkkäinen, Salme (Institute of Physics, 2021)Objective: Heart rate (HR) monitoring provides a convenient and inexpensive way to predict energy expenditure (EE) during physical activity. However, there is a lot of variation among individuals in the EE-HR relationship, ... -
Training Load and Energy Expenditure during Military Basic Training Period
Jurvelin, Heidi; Tanskanen-Tervo, Minna; Kinnunen, Hannu; Santtila, Matti; Kyröläinen, Heikki (Lippincott Williams & Wilkins, 2020)Purpose: To compare training load and energy expenditure during an 8-week military BT period among individuals having different fitness level using objective measurements in an authentic environment. Methods: Thirty-four ... -
Wearable measured physical activity profiles and variances in energy expenditure
Hirvonen, Niko-Petteri (2024)Physical activity is decreasing, and sedentary time is increasing in modern society causing health-, social-, and economic harm at both individual and community levels. The prevalence of diseases directly related to low ... -
Sex-related differences in free-living estimates of physical activity energy expenditure between older men and women
Karavirta, Laura; Rantalainen, Timo; Westgate, Kate; Aittokoski, Timo; Neuvonen, Joona; Lipponen, Jukka A.; Turunen, Katri; Nikander, Riku; Portegijs, Erja; Rantanen, Taina; Brage, Soren (Oxford University Press (OUP), 2023)Purpose Physical activity is often quantified as physical activity energy expenditure (PAEE), which may be affected by individual ability to sustain physical activity intensity. We examined if there is a true difference ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.