dc.contributor.author | hamzaoui, Hicham El | |
dc.contributor.author | Bouwmans, Géraud | |
dc.contributor.author | Capoen, Bruno | |
dc.contributor.author | Cassez, Andy | |
dc.contributor.author | Habert, Rémi | |
dc.contributor.author | Ouerdane, Youcef | |
dc.contributor.author | Girard, Sylvain | |
dc.contributor.author | francesca, Diego Di | |
dc.contributor.author | Kerboub, Nourdine | |
dc.contributor.author | Morana, Adriana | |
dc.contributor.author | Söderström, Daniel Paul | |
dc.contributor.author | Boukenter, Aziz | |
dc.contributor.author | Bouazaoui, Mohamed | |
dc.date.accessioned | 2019-04-15T05:37:57Z | |
dc.date.available | 2019-04-15T05:37:57Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | hamzaoui, H. E., Bouwmans, G., Capoen, B., Cassez, A., Habert, R., Ouerdane, Y., Girard, S., francesca, D. D., Kerboub, N., Morana, A., Söderström, D. P., Boukenter, A., & Bouazaoui, M. (2019). Gd3+-doped sol-gel silica glass for remote ionizing radiation dosimetry. <i>OSA Continuum</i>, <i>2</i>(3), 715-721. <a href="https://doi.org/10.1364/OSAC.2.000715" target="_blank">https://doi.org/10.1364/OSAC.2.000715</a> | |
dc.identifier.other | CONVID_28987936 | |
dc.identifier.other | TUTKAID_81056 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/63485 | |
dc.description.abstract | Gadolinium-doped silica glass was prepared, using the sol-gel route, for ionizing radiation dosimetry applications. Such a glassy rod was drawn to a cane at a temperature of 2000 °C. The structural and optical properties of the obtained material were studied using Raman, optical absorption, and photoluminescence spectroscopies. Thereafter, a small piece of this Gd-doped scintillating cane was spliced to a transport passive optical fiber, allowing the remote monitoring of the X-ray dose rate through a radioluminescence (RL) signal. The sample exhibited a linear RL intensity response versus the dose rate from 125 µGy(SiO2)/s up to 12.25 Gy/s. These results confirm the potentialities of this material for real-time remote ionizing radiation dosimetry. | fi |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | Optical Society of America | |
dc.relation.ispartofseries | OSA Continuum | |
dc.rights | In Copyright | |
dc.subject.other | gadolinium-doped silica glass | |
dc.title | Gd3+-doped sol-gel silica glass for remote ionizing radiation dosimetry | |
dc.type | article | |
dc.identifier.urn | URN:NBN:fi:jyu-201903292007 | |
dc.contributor.laitos | Fysiikan laitos | fi |
dc.contributor.laitos | Department of Physics | en |
dc.contributor.oppiaine | Kiihdytinlaboratorio | fi |
dc.contributor.oppiaine | Accelerator Laboratory | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.date.updated | 2019-03-29T07:15:29Z | |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.description.reviewstatus | peerReviewed | |
dc.format.pagerange | 715-721 | |
dc.relation.issn | 2578-7519 | |
dc.relation.numberinseries | 3 | |
dc.relation.volume | 2 | |
dc.type.version | publishedVersion | |
dc.rights.copyright | © 2019 Optical Society of America | |
dc.rights.accesslevel | openAccess | fi |
dc.format.content | fulltext | |
dc.rights.url | http://rightsstatements.org/page/InC/1.0/?language=en | |
dc.relation.doi | 10.1364/OSAC.2.000715 | |
dc.type.okm | A1 | |