Towards higher sensitivity at the RITU focal plane
Kettunen, H., Greenlees, P., Helariutta, K., Jones, P., Julin, R., Juutinen, S., Kuusiniemi, P., Leino, M., Muikku, M., Nieminen, P., & Uusitalo, J. (2001). Towards higher sensitivity at the RITU focal plane. Acta Physica Polonica B, 32(3), 989. http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=989
Julkaistu sarjassa
Acta Physica Polonica BTekijät
Päivämäärä
2001Tekijänoikeudet
© Authors, 2001
The recently reconstructed focal plane detector system for the gas-filled recoil separator RITU was used to observe a new proton emitter 164Ir. The nuclide was produced via the p5n fusion evaporation channel using a 64Zn beam on a 106Cd target. The proton energy Ep = 1817(9) keV and half-life T1/2 = 113+62-30 μ s were used to characterize the decaying state to be [π h11/2 ν f7/2]9+. The new focal plane detector system and the results of the proton decay studies will be discussed.
Julkaisija
Jagellonian UniversityISSN Hae Julkaisufoorumista
0587-4254Asiasanat
Alkuperäislähde
http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=989Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/26512085
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Neutrino Flavor Sensitivity of Large Liquid Scintillator Detectors
Loo, Kai; Bick, D.; Enqvist, T.; Hellgartner, D.; Kaiser, M.; Lorenz, S.; Meloni, M.; Meyer, M.; Möllenberg, R.; Oberauer, L.; Soiron, M.; Smirnov, Mikhail; Trzaska, Wladyslaw; Wonsak, B.; Wurm, M. (Elsevier BV, 2015)Scintillator detectors are known for their good light yield, energy resolution, timing characteristics and pulse shape discrimination capabilities. These features make the next-generation liquid scintillation detector ... -
Novel methods for analysis of radioactive samples using position-sensitive detectors, coincidence techniques and event-mode data acquisition
Turunen, Jani (2013)A feasibility study on event-mode data acquisition systems, the alpha–gamma coincidence technique and position-sensitive detectors was conducted in Jyväskylä in the summer of 2007. Based on this study, a measurement device ... -
The design and sensitivity of JUNO’s scintillator radiopurity pre-detector OSIRIS
JUNO Collaboration (Springer, 2021)The OSIRIS detector is a subsystem of the liquid scintillator filling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO ... -
Detector contamination monitoring system for Finnish radiation early warning network
Bogdanoff, Ville (2020)Tässä pro gradu -tutkielmassa kehitettiin ilmaisimen pinnan kontaminaation mittausjärjestelmää Suomen ulkoisen säteilyn valvontaverkon uuden sukupolven säteilymittausaseman gammailmaisimeen. Ydinvoimalaonnettomuuksissa ja ... -
Thermoelectric Radiation Detector Based on Superconductor-Ferromagnet Systems
Heikkilä, Tero; Ojajärvi, Risto; Maasilta, Ilari; Strambini, E.; Giazotto, F.; Bergeret, F. S. (American Physical Society, 2018)We suggest an ultrasensitive detector of electromagnetic fields exploiting the giant thermoelectric effect recently found in superconductor-ferromagnet hybrid structures. Compared with other types of superconducting detectors ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.