dc.contributor.author | Nesterenko, Dmitrii | |
dc.contributor.author | Canete, Laetitia | |
dc.contributor.author | Eronen, Tommi | |
dc.contributor.author | Jokinen, Ari | |
dc.contributor.author | Kankainen, Anu | |
dc.contributor.author | Novikov, Yu.N. | |
dc.contributor.author | Rinta-Antila, Sami | |
dc.contributor.author | de Roubin, Antoine | |
dc.contributor.author | Vilén, Markus | |
dc.date.accessioned | 2018-11-16T10:45:58Z | |
dc.date.available | 2021-01-03T22:35:09Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Nesterenko, D., Canete, L., Eronen, T., Jokinen, A., Kankainen, A., Novikov, Yu.N., Rinta-Antila, S., de Roubin, A., & Vilén, M. (2019). High-precision measurement of the mass difference between 102Pd and 102Ru. <i>International Journal of Mass Spectrometry</i>, <i>435</i>, 204-208. <a href="https://doi.org/10.1016/j.ijms.2018.10.038" target="_blank">https://doi.org/10.1016/j.ijms.2018.10.038</a> | |
dc.identifier.other | CONVID_28706310 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/60221 | |
dc.description.abstract | The Q-value for the neutrinoless double electron capture on 102Pd, Qϵϵ(102Pd), is determined as the atomic mass difference between 102Pd and 102Ru. A precise measurement of the Qϵϵ(102Pd) at the SHIPTRAP Penning trap showed a more than 10σ deviation to the adopted Atomic Mass Evaluation (AME) value. The reliability of the SHIPTRAP measurement was challenged because the AME value was based on numerous experiments including β and electron capture decays and very precise (n, γ) data, all agreeing with each other. To solve the discrepancy, the Qϵϵ(102Pd) has now been determined with the JYFLTRAP Penning trap at the IGISOL facility in the Accelerator Laboratory of the University of Jyväskylä. The measurement was performed both with the Time-of-Flight and the Phase-Imaging Ion Cyclotron Resonance techniques. The obtained result, Qϵϵ(102Pd) = 1203.472(45) keV, is eight times more precise and agrees well with the value obtained at SHIPTRAP, Qϵϵ(102Pd) = 1203.27(36) keV, confirming that 102Pd is not a good candidate for a search for neutrinoless double-electron capture. | fi |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | Elsevier BV | |
dc.relation.ispartofseries | International Journal of Mass Spectrometry | |
dc.rights | CC BY-NC-ND 4.0 | |
dc.subject.other | penning trap | |
dc.subject.other | high-precision mass spectrometry | |
dc.subject.other | Q-values | |
dc.subject.other | neutrinoless double-electron capture | |
dc.title | High-precision measurement of the mass difference between 102Pd and 102Ru | |
dc.type | research article | |
dc.identifier.urn | URN:NBN:fi:jyu-201811134688 | |
dc.contributor.laitos | Fysiikan laitos | fi |
dc.contributor.laitos | Department of Physics | en |
dc.contributor.oppiaine | Kiihdytinlaboratorio | fi |
dc.contributor.oppiaine | Accelerator Laboratory | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.date.updated | 2018-11-13T13:15:17Z | |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.description.reviewstatus | peerReviewed | |
dc.format.pagerange | 204-208 | |
dc.relation.issn | 1387-3806 | |
dc.relation.numberinseries | 0 | |
dc.relation.volume | 435 | |
dc.type.version | acceptedVersion | |
dc.rights.copyright | © 2018 Elsevier B.V. | |
dc.rights.accesslevel | openAccess | fi |
dc.type.publication | article | |
dc.relation.grantnumber | 295207 | |
dc.relation.grantnumber | 275389 | |
dc.relation.grantnumber | 284516 | |
dc.relation.grantnumber | 312544 | |
dc.relation.grantnumber | 306980 | |
dc.subject.yso | ydinfysiikka | |
dc.format.content | fulltext | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p14759 | |
dc.rights.url | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.relation.doi | 10.1016/j.ijms.2018.10.038 | |
dc.relation.funder | Suomen Akatemia | fi |
dc.relation.funder | Suomen Akatemia | fi |
dc.relation.funder | Suomen Akatemia | fi |
dc.relation.funder | Suomen Akatemia | fi |
dc.relation.funder | Suomen Akatemia | fi |
dc.relation.funder | Research Council of Finland | en |
dc.relation.funder | Research Council of Finland | en |
dc.relation.funder | Research Council of Finland | en |
dc.relation.funder | Research Council of Finland | en |
dc.relation.funder | Research Council of Finland | en |
jyx.fundingprogram | Akatemiatutkija, SA | fi |
jyx.fundingprogram | Akatemiatutkija, SA | fi |
jyx.fundingprogram | Akatemiatutkijan tutkimuskulut, SA | fi |
jyx.fundingprogram | Akatemiatutkijan tutkimuskulut, SA | fi |
jyx.fundingprogram | Akatemiatutkijan tutkimuskulut, SA | fi |
jyx.fundingprogram | Academy Research Fellow, AoF | en |
jyx.fundingprogram | Academy Research Fellow, AoF | en |
jyx.fundingprogram | Research costs of Academy Research Fellow, AoF | en |
jyx.fundingprogram | Research costs of Academy Research Fellow, AoF | en |
jyx.fundingprogram | Research costs of Academy Research Fellow, AoF | en |
jyx.fundinginformation | This work has been supported by the Academy of Finland by the project “State-of-the-art ion beam developments for JYFL-ACCLAB”, decision No. 273526. A.K. acknowledges the support from the Academy of Finland under Grant No. 275389 and D.N. and L.C. under Grant Nos. 284516 and 312544 . T.E. acknowledges the support from the Academy of Finland under Grant No. 295207 and A.R. under Grant No. 306980 . | |
dc.type.okm | A1 | |