Näytä suppeat kuvailutiedot

dc.contributor.authorTarvainen, Olli
dc.contributor.authorOrpana, J.
dc.contributor.authorKronholm, Risto
dc.contributor.authorKalvas, Taneli
dc.contributor.authorLaulainen, Janne
dc.contributor.authorKoivisto, Hannu
dc.contributor.authorIzotov, I.
dc.contributor.authorSkalyga, V.
dc.contributor.authorToivanen, V.
dc.date.accessioned2016-09-19T05:46:03Z
dc.date.available2016-09-19T05:46:03Z
dc.date.issued2016
dc.identifier.citationTarvainen, O., Orpana, J., Kronholm, R., Kalvas, T., Laulainen, J., Koivisto, H., Izotov, I., Skalyga, V., & Toivanen, V. (2016). The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source. <i>Review of Scientific Instruments</i>, <i>87</i>(9), Article 093301. <a href="https://doi.org/10.1063/1.4962026" target="_blank">https://doi.org/10.1063/1.4962026</a>
dc.identifier.otherCONVID_26213577
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/51394
dc.description.abstractThe efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+–O7+ were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.
dc.language.isoeng
dc.publisherAmerican Institute of Physics
dc.relation.ispartofseriesReview of Scientific Instruments
dc.subject.otherelectron cyclotron resonance ion sources
dc.subject.otherplasma chamber
dc.titleThe effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source
dc.typeresearch article
dc.identifier.urnURN:NBN:fi:jyu-201609154116
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.oppiaineKiihdytinlaboratoriofi
dc.contributor.oppiaineAccelerator Laboratoryen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2016-09-15T12:15:06Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn0034-6748
dc.relation.numberinseries9
dc.relation.volume87
dc.type.versionpublishedVersion
dc.rights.copyright© Published by AIP Publishing.
dc.rights.accesslevelopenAccessfi
dc.type.publicationarticle
dc.subject.ysomikroaallot
jyx.subject.urihttp://www.yso.fi/onto/yso/p5741
dc.relation.doi10.1063/1.4962026
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot