dc.contributor.author | Tarvainen, Olli | |
dc.contributor.author | Orpana, J. | |
dc.contributor.author | Kronholm, Risto | |
dc.contributor.author | Kalvas, Taneli | |
dc.contributor.author | Laulainen, Janne | |
dc.contributor.author | Koivisto, Hannu | |
dc.contributor.author | Izotov, I. | |
dc.contributor.author | Skalyga, V. | |
dc.contributor.author | Toivanen, V. | |
dc.date.accessioned | 2016-09-19T05:46:03Z | |
dc.date.available | 2016-09-19T05:46:03Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Tarvainen, O., Orpana, J., Kronholm, R., Kalvas, T., Laulainen, J., Koivisto, H., Izotov, I., Skalyga, V., & Toivanen, V. (2016). The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source. <i>Review of Scientific Instruments</i>, <i>87</i>(9), Article 093301. <a href="https://doi.org/10.1063/1.4962026" target="_blank">https://doi.org/10.1063/1.4962026</a> | |
dc.identifier.other | CONVID_26213577 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/51394 | |
dc.description.abstract | The efficiency of the microwave-plasma coupling plays a significant role in the production of highly
charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties
are affected by the mechanical design of the ion source plasma chamber and microwave launching
system, as well as damping of the microwave electric field by the plasma. Several experiments
attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of
the injected microwaves have been conducted with varying degrees of success. The inherent difficulty
in interpretation of the frequency tuning results is that the effects of microwave coupling system and
the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the
effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the
cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz
ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod
axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+–O7+
were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was
observed that the tuner position affects the beam currents of high charge state ions up to several
tens of percent. In particular, it was found that at some tuner position / frequency combinations
the plasma exhibited “mode-hopping” between two operating regimes. The results improve the
understanding of the role of plasma chamber cavity properties on ECRIS performances. | |
dc.language.iso | eng | |
dc.publisher | American Institute of Physics | |
dc.relation.ispartofseries | Review of Scientific Instruments | |
dc.subject.other | electron cyclotron resonance ion sources | |
dc.subject.other | plasma chamber | |
dc.title | The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source | |
dc.type | research article | |
dc.identifier.urn | URN:NBN:fi:jyu-201609154116 | |
dc.contributor.laitos | Fysiikan laitos | fi |
dc.contributor.laitos | Department of Physics | en |
dc.contributor.oppiaine | Kiihdytinlaboratorio | fi |
dc.contributor.oppiaine | Accelerator Laboratory | en |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | |
dc.date.updated | 2016-09-15T12:15:06Z | |
dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.description.reviewstatus | peerReviewed | |
dc.relation.issn | 0034-6748 | |
dc.relation.numberinseries | 9 | |
dc.relation.volume | 87 | |
dc.type.version | publishedVersion | |
dc.rights.copyright | © Published by AIP Publishing. | |
dc.rights.accesslevel | openAccess | fi |
dc.type.publication | article | |
dc.subject.yso | mikroaallot | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p5741 | |
dc.relation.doi | 10.1063/1.4962026 | |
dc.type.okm | A1 | |