Precision 71Ga – 71Ge mass-difference measurement
Alanssari, M., Frekers, D., Eronen, T., Canete, L., Hakala, J., Holl, M., Jokinen, A., Kankainen, A., Koponen, J., Moore, I., Nesterenko, D., Pohjalainen, I., Reinikainen, J., Rinta-Antila, S., & Voss, A. (2016). Precision 71Ga – 71Ge mass-difference measurement. International Journal of Mass Spectrometry, 406, 1-3. https://doi.org/10.1016/j.ijms.2016.05.019
Published in
International Journal of Mass SpectrometryAuthors
Holl, M. |
Date
2016Copyright
© 2016 Elsevier B.V. This is a final draft version of an article whose final and definitive form has been published by Elsevier. Published in this repository with the kind permission of the publisher.
The 71Ga(νe, e−)
71Ge reaction Q value has been measured with the
JYFLTRAP mass spectrometer at the IGISOL facility of the University of
Jyv¨askyl¨a to Q = 232.443(93) keV. This value agrees with previous measurements,
though it features a much higher accuracy. The Q value is being
discussed in the context of the solar neutrino capture rate in 71Ga.
Publisher
Elsevier BVISSN Search the Publication Forum
1387-3806Publication in research information system
https://converis.jyu.fi/converis/portal/detail/Publication/26039177
Metadata
Show full item recordCollections
Related items
Showing items with similar title or keywords.
-
High-precision electron-capture Q value measurement of 111In for electron-neutrino mass determination
Ge, Z.; Eronen, T.; de Roubin, A.; Tyrin, K.S.; Canete, L.; Geldhof, S.; Jokinen, A.; Kankainen, A.; Kostensalo, J.; Kotila, J.; Krivoruchenko, M.I.; Moore, I.D.; Nesterenko, D.A.; Suhonen, J.; Vilén, M. (Elsevier, 2022)A precise determination of the ground state 111In (9/2+) electron capture to ground state of 111Cd (1/2+) Q value has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. A value of 857.63(17) keV ... -
Direct high-precision measurement of the mass difference of 77As–77Se related to neutrino mass determination
Ge, Z.; Eronen, T.; Ramalho, M.; de Roubin, A.; Nesterenko D., A.; Kankainen, A.; Beliuskina, O.; de Groote, R.; Geldhof, S.; Gins, W.; Hukkanen, M.; Jokinen, A.; Koszorús, Á.; Kotila, J.; Kostensalo, J.; Moore I., D.; Pirinen, P.; Raggio, A.; Rinta-Antila, S.; Sevestrean V., A.; Suhonen, J.; Virtanen, V.; Zadvornaya, A. (Springer, 2024)The first direct determination of the ground-state-to-ground-state β−-decay Q-value of 77As to 77Se was performed by measuring their atomic mass difference utilizing the double Penning trap mass spectrometer, JYFLTRAP. The ... -
Observation of an ultralow-Q-value electron-capture channel decaying to 75As via a high-precision mass measurement
Ramalho, M.; Ge, Z.; Eronen, T.; Nesterenko, D. A.; Jaatinen, J.; Jokinen, A.; Kankainen, A.; Kostensalo, J.; Kotila, J.; Krivoruchenko, M. I.; Suhonen, J.; Tyrin, K. S.; Virtanen, V. (American Physical Society (APS), 2022)A precise determination of the atomic mass of 75As has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. The mass excess is measured to be −73035.519(42)keV/c2, which is a factor of 21 more ... -
High-precision measurements of the atomic mass and electron-capture decay Q value of 95Tc
Ge, Zhuang; Eronen, Tommi; Sevestrean, Vasile Alin; Niţescu, Ovidiu; Stoica, Sabin; Ramalho, Marlom; Suhonen, Jouni; de Roubin, Antoine; Nesterenko, Dmitrii; Kankainen, Anu; Ascher, Pauline; Ayet, San Andres Samuel; Beliuskina, Olga; Delahaye, Pierre; Flayol, Mathieu; Gerbaux, Mathias; Grévy, Stéphane; Hukkanen, Marjut; Jaries, Arthur; Jokinen, Ari; Husson, Audric; Kahl, Daid; Kostensalo, Joel; Kotila, Jenni; Moore, Iain; Nikas, Stylianos; Stryjczyk, Marek; Virtanen, Ville (Elsevier, 2024)A direct measurement of the ground-state-to-ground-state electron-capture decay Q value of 95Tc has been performed utilizing the double Penning trap mass spectrometer JYFLTRAP. The Q value was determined to be 1695.92(13) ... -
Sub-percent precision measurement of neutrino oscillation parameters with JUNO
JUNO Collaboration (IOP Publishing, 2022)