Testing of laser ablation ion source for JYFLTRAP
In this work, we have constructed and tested a laser ablation ion source for JYFLTRAP Penning trap at the IGISOL (Ion Guide Isotope Separator On-line) facility. The calibration of the Penning trap parameters requires reference ions or ion clusters that have well-known masses with relatively small mass uncertainty. These ions and ion clusters can be created with certain solid targets, which contain large amounts of isotopes of reference masses and by using a laser for target ablation. In this work simulations of ion source parameters, construction, testing and improving a laser ablation ion source setup have been done. Targets with relatively large abundances of 63Cu and 65Cu, 85Rb, 87Rb, 115In, 120Sn have been used for the laser ablation. Some of these ions were successfully created and measured with the Penning trap.
Asiasanat
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Pro gradu -tutkielmat [29739]
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Ion yields in HIGISOL experiments based on JYFLTRAP data and PACE4 simulations : based on JYFLTRAP data and PACE4 simulations
Vainio, Laura (2012)The purpose of this thesis was to calculate ion yields in the neutron-deficient mass region A=78-111 in heavy-ion ion-guide experiments at the Ion Guide Isotope Separator On-Line (IGISOL) facility in the Accelerator ... -
2021_06_02_TrapOffline: 98Mo-98Ru and 96Ru-96Mo with the JYFLTRAP Penning trap mass spectrometer
Eronen, Tommi; Nesterenko, Dimitrii; Ge, Zhuang; Kankainen, Anu (2022)Data include the measurement data collected with the JYFLTRAP double Penning trap mass spectrometer in the JYFL-ACCLAB Accelerator Laboratory at the University of Jyväskylä and the associated ELOG notes. Supplementary data ... -
Offline commissioning of the multi-reflection time-of-flight mass separator at JYFLTRAP
Virtanen, Ville (2019)Tässä työssä esitellään Jyväskylän yliopiston kiihdytinlaboratoriossa sijaitsevaan IGISOL-laitokseen rakennetun moniheijastavan lentoaika-massaerottajan (engl. Multi- Reflection Time-of-Flight mass separator, MR-ToF-ms) ... -
Initialization of the JYFLTRAP system
Pikkarainen, Toni (2013)The IGISOL facility has been moved into a new location at the acceleration laboratory of the University of Jyväskylä. The superconducting magnet that is part of the JYFLTRAP system has been re-energized. In this thesis a ... -
Rutenium-98 isotoopin tarkkuusmassamittaus JYFLTRAP Penningin loukulla
Nykänen, Tomi (2021)Rutenium-98 isotoopin atomimassa on huonoiten tunnettu kaikista stabiileista isotoopeista. Sen ajankohtaisin taulukkoarvo perustuu 1960- ja 1970-luvuilla suoritettuihin mittauksiin, minkä seurauksena massaylijäämän arvo, ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.