Offline commissioning of the multi-reflection time-of-flight mass separator at JYFLTRAP

Thumbnail
View/Open
5.9 Mb

Downloads:  
Show download detailsHide download details  
Authors
Virtanen, Ville
Date
2019
Discipline
FysiikkaPhysics
Copyright
This publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.

 
Tässä työssä esitellään Jyväskylän yliopiston kiihdytinlaboratoriossa sijaitsevaan IGISOL-laitokseen rakennetun moniheijastavan lentoaika-massaerottajan (engl. Multi- Reflection Time-of-Flight mass separator, MR-ToF-ms) käyttöönottokokeen tulokset. Massaerottaja koekäytettiin loukuttamalla ja erottamalla toisistaan samaan ionikimpuun sekoitetut 87Rb ja 85Rb-ionit. Tässä kokeessa laitteella saavutettiin 2.6 · 104 massaerotussuhdeluku 2.6 millisekunnin ajassa. Työssä kokeiltiin myös ionien massavalikoivaa lähetystä moniheijastavasta lentoaika-massaerottajasta jännitepulssitettavan keskuselektrodin avulla onnistuneesti.
 
In this work, the results from the offline characterisation of the JYFL Multi-reflection time-of-flight mass separator (MR-ToF-ms) constructed at the IGISOL-facility are presented. The separator was used to trap and separate ion bunches consisting of 87Rb and 85Rb. Mass resolving power of 2.6 · 104 was achieved in 2.6 ms in this test. During the characterisation, the use mass-selective ion ejection from the MR-ToF-ms was also tested and found viable.
 
Keywords
multi-reflection time-of-flight separaattorit massa (fysiikka) massaspektrometria ionit aika separators mass (physics) mass spectrometry ions time
URI

http://urn.fi/URN:NBN:fi:jyu-202001021002

Metadata
Show full item record
Collections
  • Pro gradu -tutkielmat [24525]

Related items

Showing items with similar title or keywords.

  • High-resolution, accurate multiple-reflection time-of-flight mass spectrometry for short-lived, exotic nuclei of a few events in their ground and low-lying isomeric states 

    Andrés, Samuel Ayet San; Hornung, Christine; Ebert, Jens; Plaß, Wolfgang R.; Dickel, Timo; Geissel, Hans; Scheidenberger, Christoph; Bergmann, Julian; Greiner, Florian; Haettner, Emma; Jesch, Christian; Lippert, Wayne; Mardor, Israel; Miskun, Ivan; Patyk, Zygmunt; Pietri, Stephane; Pihktelev, Alexander; Purushothaman, Sivaji; Reiter, Moritz P.; Rink, Ann-Kathrin; Weick, Helmut; Yavor, Mikhail I.; Bagchi, Soumya; Charviakova, Volha; Constantin, Paul; Diwisch, Marcel; Finlay, Andrew; Kaur, Satbir; Knöbel, Ronja; Lang, Johannes; Mei, Bo; Moore, Iain; Otto, Jan-Hendrik; Pohjalainen, Ilkka; Prochazka, Andrej; Rappold, Christophe; Takechi, Maya; Tanaka, Yoshiki K.; Winfield, John S.; Xu, Xiaodong (American Physical Society, 2019)
    Mass measurements of fission and projectile fragments, produced via 238 U and 124 Xe primary beams, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the Fragment ...
  • Reflectance Measurement Method Based on Sensor Fusion of Frame-Based Hyperspectral Imager and Time-of-Flight Depth Camera 

    Rahkonen, Samuli; Lind, Leevi; Raita-Hakola, Anna-Maria; Kiiskinen, Sampsa; Pölönen, Ilkka (MDPI AG, 2022)
    Hyperspectral imaging and distance data have previously been used in aerial, forestry, agricultural, and medical imaging applications. Extracting meaningful information from a combination of different imaging modalities ...
  • First spatial separation of a heavy ion isomeric beam with a multiple-reflection time-of-flight mass spectrometer 

    Dickel, T.; Plaß, W.R.; Andres, S. Ayet San; Ebert, J.; Geissel, H.; Haettner, E.; Hornung, C.; Miskun, I.; Pietri, S.; Purushothaman, S.; Reiter, M.P.; Rink, A.-K.; Scheidenberger, C.; Weick, H.; Dendooven, P.; Diwisch, M.; Greiner, F.; Heiße, F.; Knöbel, R.; Lippert, W.; Moore, Iain; Pohjalainen, Ilkka; Prochazka, A.; Ranjan, M.; Takechi, M.; Winfield, J.S.; Xu, X. (Elsevier BV * North-Holland, 2015)
    211Po ions in the ground and isomeric states were produced via 238U projectile fragmentation at 1000 MeV/u. The 211Po ions were spatially separated in flight from the primary beam and other reaction products by the ...
  • 2021_06_02_TrapOffline: 98Mo-98Ru and 96Ru-96Mo with the JYFLTRAP Penning trap mass spectrometer 

    Eronen, Tommi; Nesterenko, Dimitrii; Ge, Zhuang; Kankainen, Anu (2022)
    Data include the measurement data collected with the JYFLTRAP double Penning trap mass spectrometer in the JYFL-ACCLAB Accelerator Laboratory at the University of Jyväskylä and the associated ELOG notes. Supplementary data ...
  • Instrumentation for time-of-flight elastic recoil detection analysis 

    Julin, Jaakko (University of Jyväskylä, 2016)
    Time-of-flight elastic recoil detection is an ion beam based method to analyze the elemental composition of thin film samples at different depths. In order to improve the mass resolution and to enable kinematic correction ...
  • Browse materials
  • Browse materials
  • Articles
  • Conferences and seminars
  • Electronic books
  • Historical maps
  • Journals
  • Tunes and musical notes
  • Photographs
  • Presentations and posters
  • Publication series
  • Research reports
  • Research data
  • Study materials
  • Theses

Browse

All of JYXCollection listBy Issue DateAuthorsSubjectsPublished inDepartmentDiscipline

My Account

Login

Statistics

View Usage Statistics
  • How to publish in JYX?
  • Self-archiving
  • Publish Your Thesis Online
  • Publishing Your Dissertation
  • Publication services

Open Science at the JYU
 
Data Protection Description

Accessibility Statement

Unless otherwise specified, publicly available JYX metadata (excluding abstracts) may be freely reused under the CC0 waiver.
Open Science Centre