Recalibration of Beam Evaluation Tool
Tekijät
Päivämäärä
2024Tekijänoikeudet
Julkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.
Due to the harsh radiation environment in space the electronic devices may experience malfunction and even damaging effects caused by Single Event Effects. In order to verify the radiation tolerance of the devices, the test must be performed with a radiation beam before the mission. In order to obtain more reliable results of the test, the Beam Evaluation Tool was developed at CNES (BET-C). BET-C is designed to validate the particle energy and the distribution of the beam during the tests. The tool is utilising a position sensitive detector. The system is still under improvement after it was partially modified. Due to modifications, recalibration of the system was in order. Both energy calculation and position distribution had certain inaccuracies which were corrected by determining the calibration functions. The correction functions were established by using the non processed data extracted from the test campaign at UCLouvain where the BET-C system was tested under high energy ion beams. The results obtained with calibration function show considerable improvement in position distribution for all the ions. Regarding the energy, values close to the theoretical ones were achieved by using the data extracted from measurements with aluminium, chromium, nickel and rhodium. During measurements with carbon the position distribution was not detected and the raw signal that was obtained was too weak to include Carbon in the calibration. With xenon the upper limit of detection was reached leading to the conclusion that the optimal energy range for detection is between 250 MeV and 995 MeV.
...
Asiasanat
Metadata
Näytä kaikki kuvailutiedotKokoelmat
- Pro gradu -tutkielmat [29574]
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Neutrino Flavor Sensitivity of Large Liquid Scintillator Detectors
Loo, Kai; Bick, D.; Enqvist, T.; Hellgartner, D.; Kaiser, M.; Lorenz, S.; Meloni, M.; Meyer, M.; Möllenberg, R.; Oberauer, L.; Soiron, M.; Smirnov, Mikhail; Trzaska, Wladyslaw; Wonsak, B.; Wurm, M. (Elsevier BV, 2015)Scintillator detectors are known for their good light yield, energy resolution, timing characteristics and pulse shape discrimination capabilities. These features make the next-generation liquid scintillation detector ... -
The design and sensitivity of JUNO’s scintillator radiopurity pre-detector OSIRIS
JUNO Collaboration (Springer, 2021)The OSIRIS detector is a subsystem of the liquid scintillator filling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO ... -
Novel methods for analysis of radioactive samples using position-sensitive detectors, coincidence techniques and event-mode data acquisition
Turunen, Jani (2013)A feasibility study on event-mode data acquisition systems, the alpha–gamma coincidence technique and position-sensitive detectors was conducted in Jyväskylä in the summer of 2007. Based on this study, a measurement device ... -
Overview of High-Performance Timing and Position-Sensitive MCP Detectors Utilizing Secondary Electron Emission for Mass Measurements of Exotic Nuclei at Nuclear Physics Facilities
Ge, Zhuang (MDPI, 2024)Timing and/or position-sensitive MCP detectors, which detect secondary electrons (SEs) emitted from a conversion foil during ion passage, are widely utilized in nuclear physics and nuclear astrophysics experiments. This ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.