Näytä suppeat kuvailutiedot

dc.contributor.authorJohnson, M.A.
dc.contributor.authorBertsche, W.A.
dc.contributor.authorCortázar, O.D
dc.contributor.authorFaircloth, D.
dc.contributor.authorKalvas, T.
dc.contributor.authorLawrie, S.
dc.contributor.authorMegia Macías, A.M.
dc.contributor.authorTarvainen, O.
dc.contributor.authorBarrios Díaz, E.
dc.date.accessioned2024-05-23T11:32:01Z
dc.date.available2024-05-23T11:32:01Z
dc.date.issued2024
dc.identifier.citationJohnson, M.A., Bertsche, W.A., Cortázar, O.D, Faircloth, D., Kalvas, T., Lawrie, S., Megia Macías, A.M., Tarvainen, O., & Barrios Díaz, E. (2024). Development and commissioning of a hydrogen ion source for the CERN ALPHA experiment. <i>Journal of Instrumentation</i>, <i>19</i>(1), Article C01021. <a href="https://doi.org/10.1088/1748-0221/19/01/C01021" target="_blank">https://doi.org/10.1088/1748-0221/19/01/C01021</a>
dc.identifier.otherCONVID_215902269
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/95119
dc.description.abstractThe CERN ALPHA experiment makes precision measurements of antihydrogen atoms held in a superconducting magnetic minimum trap. Recent studies of the antihydrogen spectrum have provided unique tests of fundamental physics, and to improve on these studies ALPHA is now proposing upgrades to directly compare hydrogen and antihydrogen within their existing atom trap. One route towards producing cold, neutral hydrogen atoms is the integration of a hydrogen ion source into the experiment. Ideally, this should provide both positive (H+, H2+, H3+) and negative (H-) ions to facilitate different schemes for producing and trapping hydrogen atoms. For compatibility with ALPHA's existing beamlines, the source must produce modest (∼ 10 μA) beam currents at very low final energies (<100 eV). PELLIS, previously developed at JYFL, is a filament-driven ion source that generates 5–10 keV H- beams with small emittances and tens of microamps of beam current. Here, we present a modified PELLIS design to provide both positive and negative hydrogen ions for ALPHA. The use of an electromagnet filter field in PELLIS allows for the optimisation of H- volume production, and also tuning of the positive ion species fraction. We present simulations of H- (and similarly H+) transport through the initial extraction optics, which have been configured for a lower beam energy of 5 keV and designed to match a proposed beamline to interface with ALPHA. We present the results of detailed vacuum simulations that were used to guide the optics design, allowing the source (at 10-2 mbar) to interface with a transport beamline ∼ 0.5 m downstream that has strict vacuum requirements of < 10-9 mbar. We present experimental results from commissioning of the source, and show that it broadly performs as designed for both positive and negative hydrogen ions.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherIOP Publishing
dc.relation.ispartofseriesJournal of Instrumentation
dc.rightsCC BY 4.0
dc.titleDevelopment and commissioning of a hydrogen ion source for the CERN ALPHA experiment
dc.typeresearch article
dc.identifier.urnURN:NBN:fi:jyu-202405233883
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn1748-0221
dc.relation.numberinseries1
dc.relation.volume19
dc.type.versionpublishedVersion
dc.rights.copyright© 2024 the Authors
dc.rights.accesslevelopenAccessfi
dc.type.publicationarticle
dc.subject.ysohiukkasfysiikka
dc.subject.ysoionit
dc.subject.ysotutkimuslaitteet
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p15576
jyx.subject.urihttp://www.yso.fi/onto/yso/p9015
jyx.subject.urihttp://www.yso.fi/onto/yso/p2440
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/
dc.relation.doi10.1088/1748-0221/19/01/C01021
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

CC BY 4.0
Ellei muuten mainita, aineiston lisenssi on CC BY 4.0