Show simple item record

dc.contributor.authorMcPhail, Jonathan
dc.contributor.authorGonçalves, Basílio A. M.
dc.contributor.authorSpörri, Jörg
dc.contributor.authorLinnamo, Vesa
dc.date.accessioned2021-08-18T05:59:02Z
dc.date.available2021-08-18T05:59:02Z
dc.date.issued2021
dc.identifier.citationMcPhail, J., Gonçalves, B. A. M., Spörri, J., & Linnamo, V. (2021). Unilateral Maximal Isometric Hex Bar Pull Test : Within-Session Reliability and Lower Body Force Production in Male and Female Freeski Athletes. <i>Frontiers in Sports and Active Living</i>, <i>3</i>, Article 715833. <a href="https://doi.org/10.3389/fspor.2021.715833" target="_blank">https://doi.org/10.3389/fspor.2021.715833</a>
dc.identifier.otherCONVID_99260517
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/77390
dc.description.abstractThe aim of the study was to (1) assess the within-session reliability of a unilateral isometric hex bar pull (UIHBP) maximal voluntary contraction (MVC) test and, (2) determine unilateral isometric absolute peak force (PFabs) and relative peak force (PF) values in freeski athletes. Twenty-one male and eight female academy to national team freeskiers performed the novel UIHBP MVC task on a force plate and PFabs and relative PF were assessed (1000 Hz). Within-session measures of PFabs offered high reliability on left and right limbs for males (ICC = 0.91–0.94, CV = 2.6–2.2%) and females (ICC = 0.94–0.94, CV = 1.4–1.6%), while relative PF measures showed good to high reliability in both left and right limbs for males (ICC = 0.8–0.84, CV = 2.6–2.2%) and females (ICC = 0.92–0.90, CV = 1.4–1.7%). We observed significantly lower PFabs (p < 0.001) and relative PF (p < 0.001) in females compared to males. No statistical difference was found between left and right limbs in males and females in PFabs (p = 0.98) and relative PF measures (p = 0.93). The UIHBP MVC test appears to be a reliable method for assessing PFabs and relative PF in male and female freeski athletes.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherFrontiers Media SA
dc.relation.ispartofseriesFrontiers in Sports and Active Living
dc.rightsCC BY 4.0
dc.subject.otherfreeskiing
dc.subject.otherskiing
dc.subject.otherstrength testing
dc.subject.otherunilateral
dc.subject.otherisometric
dc.subject.othermaximal
dc.subject.othervoluntary
dc.subject.othercontraction
dc.titleUnilateral Maximal Isometric Hex Bar Pull Test : Within-Session Reliability and Lower Body Force Production in Male and Female Freeski Athletes
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-202108184553
dc.contributor.laitosLiikuntatieteellinen tiedekuntafi
dc.contributor.laitosFaculty of Sport and Health Sciencesen
dc.contributor.oppiaineBiomekaniikkafi
dc.contributor.oppiaineBiomechanicsen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn2624-9367
dc.relation.volume3
dc.type.versionpublishedVersion
dc.rights.copyright© 2021 the Authors
dc.rights.accesslevelopenAccessfi
dc.subject.ysovoimantuotto (fysiologia)
dc.subject.ysobiomekaniikka
dc.subject.ysofreestyle
dc.subject.ysoalppilajit
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p25323
jyx.subject.urihttp://www.yso.fi/onto/yso/p20292
jyx.subject.urihttp://www.yso.fi/onto/yso/p8086
jyx.subject.urihttp://www.yso.fi/onto/yso/p8333
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/
dc.relation.doi10.3389/fspor.2021.715833
dc.type.okmA1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC BY 4.0
Except where otherwise noted, this item's license is described as CC BY 4.0