Näytä suppeat kuvailutiedot

dc.contributor.authorRantalainen, Timo
dc.contributor.authorKaravirta, Laura
dc.contributor.authorPirkola, Henrikki
dc.contributor.authorRantanen, Taina
dc.contributor.authorLinnamo, Vesa
dc.date.accessioned2020-05-20T11:51:49Z
dc.date.available2020-05-20T11:51:49Z
dc.date.issued2020
dc.identifier.citationRantalainen, T., Karavirta, L., Pirkola, H., Rantanen, T., & Linnamo, V. (2020). Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults. <i>Sensors</i>, <i>20</i>(10), Article 2858. <a href="https://doi.org/10.3390/s20102858" target="_blank">https://doi.org/10.3390/s20102858</a>
dc.identifier.otherCONVID_35685638
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/69121
dc.description.abstractGait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (multiscale sample entropy) was evaluated from the waist-worn IMU. The force plate indicated excellent stride duration variability reliability (intra-class correlation coefficient, ICC = 0.90), whereas fair to good reliability (ICC = 0.47 to 0.66) was observed from the IMUs. The IMUs exhibited poor to excellent concurrent validity in stride duration variability compared to the force plate (ICC = 0.22 to 0.93). A good to excellent reliability was observed for gait complexity in most coarseness scales (ICC = 0.60 to 0.82). A reasonable congruence with the force plate-measured stride duration variability was observed on many coarseness scales (correlation coefficient = 0.38 to 0.83). In conclusion, waist-worn IMU entropy estimates may provide a feasible indicator of gait variability among community-dwelling ambulatory older adults.en
dc.format.mimetypeapplication/pdf
dc.languageeng
dc.language.isoeng
dc.publisherMDPI
dc.relation.ispartofseriesSensors
dc.rightsCC BY 4.0
dc.subject.otherwearable
dc.subject.othergait
dc.subject.otheraccelerometer
dc.subject.otherdynamics
dc.subject.othernon-linear
dc.titleGait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-202005203374
dc.contributor.laitosLiikuntatieteellinen tiedekuntafi
dc.contributor.laitosFaculty of Sport and Health Sciencesen
dc.contributor.oppiaineBiomekaniikkafi
dc.contributor.oppiaineGerontologia ja kansanterveysfi
dc.contributor.oppiaineBiomechanicsen
dc.contributor.oppiaineGerontology and Public Healthen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn1424-8220
dc.relation.numberinseries10
dc.relation.volume20
dc.type.versionpublishedVersion
dc.rights.copyright© 2020 by the authors. Licensee MDPI, Basel, Switzerland.
dc.rights.accesslevelopenAccessfi
dc.relation.grantnumber693045
dc.relation.grantnumber693045
dc.relation.grantnumber321336
dc.relation.grantnumber328818
dc.relation.grantnumber310526
dc.relation.projectidinfo:eu-repo/grantAgreement/EC/H2020/693045/EU//AGNES
dc.subject.ysoliikeanalyysi
dc.subject.ysokävely
dc.subject.ysobiomekaniikka
dc.subject.ysoikääntyneet
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p24952
jyx.subject.urihttp://www.yso.fi/onto/yso/p3706
jyx.subject.urihttp://www.yso.fi/onto/yso/p20292
jyx.subject.urihttp://www.yso.fi/onto/yso/p2433
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/
dc.relation.doi10.3390/s20102858
dc.relation.funderEuropean Commissionen
dc.relation.funderResearch Council of Finlanden
dc.relation.funderResearch Council of Finlanden
dc.relation.funderResearch Council of Finlanden
dc.relation.funderEuroopan komissiofi
dc.relation.funderSuomen Akatemiafi
dc.relation.funderSuomen Akatemiafi
dc.relation.funderSuomen Akatemiafi
jyx.fundingprogramERC European Research Council, H2020en
jyx.fundingprogramAcademy Research Fellow, AoFen
jyx.fundingprogramResearch costs of Academy Research Fellow, AoFen
jyx.fundingprogramAcademy Project, AoFen
jyx.fundingprogramERC European Research Council, H2020fi
jyx.fundingprogramAkatemiatutkija, SAfi
jyx.fundingprogramAkatemiatutkijan tutkimuskulut, SAfi
jyx.fundingprogramAkatemiahanke, SAfi
jyx.fundinginformationRantalainen was an Academy Research Fellow during the preparation of this manuscript (Academy of Finland grant numbers 321336 and 328818). Rantanen was supported by grants of the European Research Council (grant number 693045) and the Academy of Finland (grant number 310526).
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

CC BY 4.0
Ellei muuten mainita, aineiston lisenssi on CC BY 4.0