Optimal shape design of an electromagnet
Salmenjoki, K., Neittaanmäki, P. Arumugam, G. (1989). Optimal shape design of an electromagnet. ZAMM, 69 (4), T234-T237.
Published in
ZAMMDate
1989Access restrictions
Copyright
© Wiley
Optimal shape design of an electromagnet is considered. The aim is to find the shape of the poles in such way that the magnetic field is constant and equal to a given value in the interpolar region. A sensitivity analysis is given. Two numerical examples illustrate the results.
Publisher
WileyISSN Search the Publication Forum
0044-2267Metadata
Show full item recordCollections
License
Related items
Showing items with similar title or keywords.
-
Electromagnetic scattering solutions for digital signal processing
Blackledge, Jonathan (University of Jyväskylä, 2010) -
Excited states in 87Br populated in β decay of 87Se
Wisniewski, J.; Urban, W.; Czerwinski, M.; Kurpeta, J.; Plochocki, A.; Pomorski, M.; Rzaca-Urban, T.; Sieja, K.; Canete, L.; Eronen, T.; Geldhof, S.; Jokinen, A.; Kankainen, A.; Moore, I. D.; Nesterenko, D. A.; Penttilä, H.; Pohjalainen, I.; Rinta-Antila, S.; de Roubin, A.; Vilén, M. (American Physical Society, 2019)Excited levels in 87Br, populated in β decay of 87Se, have been studied by means of γ-ray spectroscopy using an array of broad energy Ge detectors. 87Se nuclei were produced by irradiating a natural Th target with 25-MeV ... -
First β-decay scheme of 107Nb : New insight into the low-energy levels of 107Mo
Kurpeta, J.; Płochocki, A.; Urban, W.; Abramuk, A.; Canete, L.; Eronen, T.; Fijałkowska, A; Geldhof, S.; Gotowicka, K.; Jokinen, A.; Kankainen, A.; Moore, I. D.; Nesterenko, D.; Penttilä, H.; Pohjalainen, I.; Pomorski, M.; Reponen, M.; Rinta-Antila, S.; de Roubin, A.; Rząca-Urban, T.; Vilén, M.; Wiśniewski, J. (American Physical Society, 2019)Monoisotopic samples of 107Nb nuclei, produced in the proton-induced fission of 238U and separated using the IGISOL mass separator coupled to a Penning trap, were used to perform β- and γ-coincidence spectroscopy of 107Mo. ... -
β decay of 127Cd and excited states in 127In
Lorenz, Ch.; Sarmiento, L. G.; Rudolph, D.; Golubev, P.; Eronen, Tommi; Nesterenko, Dmitrii; Kankainen, Anu; Canete, Laetitia; Cox, Daniel; Fernandez, A.; Forsberg, U.; Jungclaus, A.; Kojouharov, I.; Kurz, N.; Lalovic, N.; Partanen, Jari; Reponen, Mikael; Rinta-Antila, Sami; de Roubin, Antoine; Såmark-Roth, A.; Vaquero, V.; Vilén, Markus (American Physical Society, 2019)A dedicated spectroscopic study of the β decay of 127Cd was conducted at the IGISOL facility at the University of Jyväskylä. Following high-resolution mass separation in a Penning trap, β−γ−γcoincidences were used to ... -
Pulsed electromagnetic field therapy in the treatment of pain and other symptoms in fibromyalgia : a randomized controlled study
Multanen, Juhani; Häkkinen, Arja; Heikkinen, Pauli; Kautiainen, Hannu; Mustalampi, Sirpa; Ylinen, Jari (John Wiley & Sons, Inc., 2018)Low‐energy pulsed electromagnetic field (PEMF) therapy has been suggested as a promising therapy to increase microcirculation, which is of great concern in patients with fibromyalgia. This study evaluated the effectiveness ...