Näytä suppeat kuvailutiedot

dc.contributor.authorRahkila, Panu
dc.contributor.authorGrahn, Tuomas
dc.contributor.authorEskola, Kari
dc.contributor.authorGerl, J.
dc.contributor.authorGreenlees, Paul
dc.contributor.authorJones, P.
dc.contributor.authorJoss, D. T.
dc.contributor.authorJulin, Rauno
dc.contributor.authorJuutinen, Sakari
dc.contributor.authorKankaanpää, Harri
dc.contributor.authorKeenan, A.
dc.contributor.authorKettunen, Heikki
dc.contributor.authorKojouharov, I.
dc.contributor.authorKuusiniemi, Pasi
dc.contributor.authorLeino, Matti
dc.contributor.authorMelarangi, A.
dc.contributor.authorMoore, C. J.
dc.contributor.authorMuikku, Maarit
dc.contributor.authorNieminen, Päivi
dc.contributor.authorPage, R. D.
dc.contributor.authorScholey, C.
dc.contributor.authorUusitalo, Juha
dc.date.accessioned2019-02-20T07:30:47Z
dc.date.available2019-02-20T07:30:47Z
dc.date.issued2001
dc.identifier.citationRahkila, P., Grahn, T., Eskola, K., Gerl, J., Greenlees, P., Jones, P., Joss, D. T., Julin, R., Juutinen, S., Kankaanpää, H., Keenan, A., Kettunen, H., Kojouharov, I., Kuusiniemi, P., Leino, M., Melarangi, A., Moore, C. J., Muikku, M., Nieminen, P., . . . Uusitalo, J. (2001). Characteristics of segmented super clover detector in close geometry decay measurements. <i>Acta Physica Polonica B</i>, <i>32</i>(3), 773. <a href="http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=773" target="_blank">http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=773</a>
dc.identifier.otherCONVID_26474045
dc.identifier.otherTUTKAID_7259
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/62878
dc.description.abstractCharacteristics of the segmented Super Clover germanium detector response in close geometries have been studied. Results obtained with localising hit pattern recognition are compared with results from add-back and individual crystal analysis. The detector has been used at the focal plane of a gas filled recoil separator to detect isomeric gamma-rays from the nuclei produced in the 150Sm(42Ca,4n)188Pb reaction. Coincidence data from the detector was analysed and the level scheme below the 1.2 μ s isomeric state in 188Pb could be deduced.fi
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherJagellonian University
dc.relation.ispartofseriesActa Physica Polonica B
dc.relation.urihttp://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=773
dc.rightsCC BY 4.0
dc.subject.othernuclei
dc.subject.otherproton emission
dc.titleCharacteristics of segmented super clover detector in close geometry decay measurements
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-201902071455
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2019-02-07T10:15:05Z
dc.description.reviewstatuspeerReviewed
dc.format.pagerange773
dc.relation.issn0587-4254
dc.relation.numberinseries3
dc.relation.volume32
dc.type.versionpublishedVersion
dc.rights.copyright© Authors, 2001
dc.rights.accesslevelopenAccessfi
dc.format.contentfulltext
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

CC BY 4.0
Ellei muuten mainita, aineiston lisenssi on CC BY 4.0