dc.identifier.citationYang, Y., Schumann, M., Le, S., & Cheng, S. (2018). Reliability and validity of a new accelerometer-based device for detecting physical activities and energy expenditure. <i>PeerJ</i>, <i>6</i>, Article e5775. <a href="https://doi.org/10.7717/peerj.5775" target="_blank">https://doi.org/10.7717/peerj.5775</a>
dc.identifier.otherCONVID_28664111
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/60012
dc.description.abstractBackground Objective assessments of sedentary behavior and physical activity (PA) by using accelerometer-based wearable devices are ever expanding, given their importance in the global context of health maintenance. This study aimed to determine the reliability and validity of a new accelerometer-based analyzer (Fibion) for detecting different PAs and estimating energy expenditure (EE) during a simulated free-living day. Methods The study consisted of two parts: a reliability (n = 18) and a validity (n = 19) test. Reliability was assessed by a 45 min protocol of repeated sitting, standing, and walking (i.e., 3 × 15 min, repeated twice), using both Fibion and ActiGraph. Validity was assessed by a 12 h continuous sequence tasks of different types (sitting, standing, walking, and cycling) and intensities (light [LPA], moderate [MPA], and vigorous [VPA]) of PA. Two Fibion devices were worn on the thigh (FT) and in the pocket (FP), respectively and were compared with criteria measures, such as direct observation (criterion 1) and oxygen consumption by a portable gas analyzer, K4b2 (criterion 2). Results FT (intra-class correlation coefficients (ICCs): 0.687–0.806) provided similar reliability as the Actigraph (ICCs: 0.661–0.806) for EE estimation. However, the measurement error (ME) of FT compared to the actual time records indicated an underestimation of duration by 5.1 ± 1.2%, 3.8 ± 0.3% and 14.9 ± 2.6% during sitting, walking, and standing, respectively. During the validity test, FT but not FP showed a moderate agreement but lager variance with the criteria (1 and 2) in assessing duration of sitting, long sitting, LPA, MPA, and VPA (p > 0.05, ICCs: 0.071–0.537), as well as for EE estimation of standing, LPA, MPA, and VPA (p > 0.05, ICCs: 0.673–0.894). Conclusions FT provided similar reliability to that of the Actigraph. However, low correlations between subsequent measurements of both devices indicated large random MEs, which were somewhat diminished during the simulated 12 h real-life test. Furthermore, FT may accurately determine the types, intensities of PA and EE during prolonged periods with substantial changes in postures, indicating that the location of the accelerometer is essential. Further study with a large cohort is needed to confirm the usability of Fibion, especially for detecting the low-intensity PAs.fi
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherPeerJ Inc.
dc.relation.ispartofseriesPeerJ
dc.rightsCC BY 4.0
dc.subject.otheractivity tracker
dc.subject.otherposture allocation
dc.subject.othersedentary behavior
dc.titleReliability and validity of a new accelerometer-based device for detecting physical activities and energy expenditure
dc.typeresearch article
dc.identifier.urnURN:NBN:fi:jyu-201810164438
dc.contributor.laitosLiikuntatieteellinen tiedekuntafi
dc.contributor.laitosFaculty of Sport and Health Sciencesen
dc.contributor.oppiaineLiikuntalääketiedefi
dc.contributor.oppiaineSports and Exercise Medicineen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2018-10-16T12:15:14Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn2167-8359
dc.relation.numberinseries0
dc.relation.volume6
dc.type.versionpublishedVersion
dc.rights.copyright© 2018 Yang et al.
dc.rights.accesslevelopenAccessfi
dc.type.publicationarticle
dc.subject.ysofyysinen aktiivisuus
dc.subject.ysoliikkuminen
dc.subject.ysomittauslaitteet
dc.subject.ysoreliabiliteetti
dc.subject.ysovaliditeetti
dc.subject.ysoliike
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p23102
jyx.subject.urihttp://www.yso.fi/onto/yso/p649
jyx.subject.urihttp://www.yso.fi/onto/yso/p3583
jyx.subject.urihttp://www.yso.fi/onto/yso/p9970
jyx.subject.urihttp://www.yso.fi/onto/yso/p19898
jyx.subject.urihttp://www.yso.fi/onto/yso/p706
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/
dc.relation.doi10.7717/peerj.5775
dc.type.okmA1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

CC BY 4.0
Except where otherwise noted, this item's license is described as CC BY 4.0