Näytä suppeat kuvailutiedot

dc.contributor.authorPalosaari, Mikko
dc.contributor.authorKinnunen, Kimmo
dc.contributor.authorJulin, Jaakko
dc.contributor.authorLaitinen, Mikko
dc.contributor.authorNapari, Mari
dc.contributor.authorSajavaara, Timo
dc.contributor.authorDoriese, W. B.
dc.contributor.authorFowler, J.
dc.contributor.authorReintsema, C.
dc.contributor.authorSwetz, D.
dc.contributor.authorSchmidt, D.
dc.contributor.authorUllom, J.
dc.contributor.authorMaasilta, Ilari
dc.date.accessioned2017-07-04T09:30:51Z
dc.date.available2017-07-04T09:30:51Z
dc.date.issued2014
dc.identifier.citationPalosaari, M., Kinnunen, K., Julin, J., Laitinen, M., Napari, M., Sajavaara, T., Doriese, W. B., Fowler, J., Reintsema, C., Swetz, D., Schmidt, D., Ullom, J., & Maasilta, I. (2014). Transition-Edge Sensors for Particle Induced X-ray Emission Measurements. <i>Journal of Low Temperature Physics</i>, <i>176</i>(3-4), 285-290. <a href="https://doi.org/10.1007/s10909-013-1004-5" target="_blank">https://doi.org/10.1007/s10909-013-1004-5</a>
dc.identifier.otherCONVID_23756521
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/54831
dc.description.abstractIn this paper we present a new measurement setup, where a transitionedge sensor detector array is used to detect X-rays in particle induced X-ray emission measurements with a 2 MeV proton beam. Transition-edge sensors offer orders of magnitude improvement in energy resolution compared to conventional silicon or germanium detectors, making it possible to recognize spectral lines in materials analysis that have previously been impossible to resolve, and to get chemical information from the elements. Our sensors are cooled to the operation temperature (∼ 65 mK) with a cryogen-free adiabatic demagnetization refrigerator, which houses a specially designed X-ray snout that has a vacuum tight window to couple in the radiation. For the best pixel, the measured instrumental energy resolution was 3.06 eV full width at half maximum at 5.9 keV. We discuss the current status of the project, benefits of transition-edge sensors when used in particle induced X-ray emission spectroscopy, and the results from the first measurements.
dc.language.isoeng
dc.publisherSpringer New York LLC
dc.relation.ispartofseriesJournal of Low Temperature Physics
dc.subject.othertransition-edge sensor
dc.subject.otherTES
dc.subject.otherparticle induced X-ray emission (PIXE)
dc.titleTransition-Edge Sensors for Particle Induced X-ray Emission Measurements
dc.typeresearch article
dc.identifier.urnURN:NBN:fi:jyu-201706283128
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.oppiaineFysiikkafi
dc.contributor.oppiaineNanoscience Centerfi
dc.contributor.oppiainePhysicsen
dc.contributor.oppiaineNanoscience Centeren
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.date.updated2017-06-28T03:17:35Z
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.format.pagerange285-290
dc.relation.issn0022-2291
dc.relation.numberinseries3-4
dc.relation.volume176
dc.type.versionacceptedVersion
dc.rights.copyright© Springer Science+Business Media New York 2013. This is a final draft version of an article whose final and definitive form has been published by Springer. Published in this repository with the kind permission of the publisher.
dc.rights.accesslevelopenAccessfi
dc.type.publicationarticle
dc.relation.doi10.1007/s10909-013-1004-5
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot