Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of 23 Na 1+ ions
Tarvainen, O., Koivisto, H., Galatà, A., Angot, J., Lamy, T., Thuillier, T., Delahaye, P., Maunoury, L., Mascali, D., & Neri, L. (2016). Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of 23 Na 1+ ions. Physical Review Accelerators and Beams, 19(5), Article 053402. https://doi.org/10.1103/PhysRevAccelBeams.19.053402
Julkaistu sarjassa
Physical Review Accelerators and BeamsTekijät
Lamy, T. |
Päivämäärä
2016Tekijänoikeudet
© the Authors, 2016. This is an open access article published by American Physical Society and distributed under the terms of a e Creative Commons Attribution 3.0 License.
This work describes the utilization of an injected 23Na1þ ion beam as a diagnostics of the helium plasma
of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper
limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision
frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The
ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz
and the plasma density is estimated to be on the order of 1011 cm−3 or higher. The experimental results are
compared to simulations of the 23Na1þ capture into the helium plasma. The results indicate that the lower
breeding efficiency of light ions in comparison to heavier elements is probably due to different capture
efficiencies in which the in-flight ionization of the incident 1þ ions plays a vital role.
Julkaisija
American Physical SocietyISSN Hae Julkaisufoorumista
1098-4402Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/26128743
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Ellei muuten mainita, aineiston lisenssi on © the Authors, 2016. This is an open access article published by American Physical Society and distributed under the terms of a e Creative Commons Attribution 3.0 License.
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
The effects of electron energy distribution and ionization cross section uncertainty on charge breeder ion source diagnostics with pulsed 1+ injection
Luntinen, M.; Angot, J.; Koivisto, H.; Tarvainen, O.; Thuillier, T.; Toivanen, V. (AIP Publishing, 2023)The consecutive transients (CT) method is a plasma diagnostic technique of charge breeder electron cyclotron resonance ion source plasmas. It is based on the short-pulse injection of singly charged ions and the measurement ... -
Dynamic regimes of cyclotron instability in the afterglow mode of minimum-B electron cyclotron resonance ion source plasma
Mansfeld, D.; Izotov, I.; Skalyga, V.; Tarvainen, Olli; Kalvas, Taneli; Koivisto, Hannu; Komppula, Jani; Kronholm, Risto; Laulainen, Janne (Institute of Physics Publishing, 2016)The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion ... -
Characteristic Kα emission of electron cyclotron resonance ion source plasmas
Sakieldien, Moenir (University of Jyväskylä, 2018)This thesis presents the results of an investigation of the volumetric Kα emission rate/inner shell ionization rate from an Electron Cyclotron Resonance Ion Source (ECRIS) plasma tuned predominantly for high charge state ... -
Measurement of ionization, charge exchange and ion confinement times in charge breeder ECR ion sources with short pulse 1+ injection of metal ions
Luntinen, Miha; Angot, Julien; Tarvainen, Olli; Toivanen, Ville; Thuillier, Thomas; Koivisto, Hannu (IOP Publishing, 2022)The Consecutive Transients (CT) method is used for estimating the characteristic times of ionization, charge exchange and confinement within the plasma of a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). ... -
Estimating ion confinement times from beam current transients in conventional and charge breeder ECRIS
Marttinen, M.; Angot, J.; Annaluru, A.; Jardin, P.; Kalvas, T.; Koivisto, H.; Kosonen, S.; Kronholm, R.; Maunoury, L.; Tarvainen, O.; Toivanen, V.; Ujic, P. (American Institute of Physics, 2020)Cumulative ion confinement times are probed by measuring decaying ion current transients in pulsed material injection mode. The method is applied in a charge breeder and conventional ECRIS yielding mutually corroborative ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.