dc.identifier.citation | Harjupatana, T., Alaraudanjoki, J., & Kataja, M. (2015). X-ray tomographic method for measuring 3D deformation and liquid content in swelling materials. In R. Kouhia, J. Mäkinen, S. Pajunen, & T. Saksala (Eds.), <i>Proceedings of the XII Finnish Mechanics Days : Suomen XXII mekaniikkapäivien esietlmät</i> (pp. 222-227). Rakenteiden mekaniikan seura. | |
dc.identifier.isbn | 978-952-93-5608-9 | |
dc.identifier.other | CONVID_25427275 | |
dc.identifier.uri | https://jyx.jyu.fi/handle/123456789/48678 | |
dc.description.abstract | A non-invasive method for measuring the three-dimensional displacement field and liquid
content distribution in a wetting and swelling material using X-ray tomographic imaging is introduced.
The method is demonstrated here in monitoring the evolution of 3D deformation and water content
distributions in cylindrical samples of swelling clay material wetted in a constant total volume. The measurements
were carried out using a high-resolution microtomographic device (SkyScan 1172) and image
voxel size 24 µm. The results obtained are repeatable and appear qualitatively correct and plausible.
They are useful e.g. in validating models involving transport of water and the resulting deformation of
swelling materials. The method is potentially applicable also in other materials and processes involving
liquid transport and deformation. | |
dc.format.extent | 284 | |
dc.language.iso | eng | |
dc.publisher | Rakenteiden mekaniikan seura | |
dc.relation.ispartof | Proceedings of the XII Finnish Mechanics Days : Suomen XXII mekaniikkapäivien esietlmät | |
dc.subject.other | x-ray tomography | |
dc.subject.other | liquid content | |
dc.subject.other | liquid transport | |
dc.subject.other | deformation | |
dc.subject.other | swelling | |
dc.subject.other | wetting | |
dc.title | X-ray tomographic method for measuring 3D deformation and liquid content in swelling materials | |
dc.type | conference paper | |
dc.identifier.urn | URN:NBN:fi:jyu-201601081043 | |
dc.contributor.laitos | Fysiikan laitos | fi |
dc.contributor.laitos | Department of Physics | en |
dc.type.uri | http://purl.org/eprint/type/ConferencePaper | |
dc.date.updated | 2016-01-08T10:15:03Z | |
dc.relation.isbn | 978-952-93-5608-9 | |
dc.type.coar | http://purl.org/coar/resource_type/c_5794 | |
dc.description.reviewstatus | nonPeerReviewed | |
dc.format.pagerange | 222-227 | |
dc.type.version | publishedVersion | |
dc.rights.copyright | © The Authors, 2015. Open access under CC BY-SA 4.0 license. | |
dc.rights.accesslevel | openAccess | fi |
dc.type.publication | conferenceObject | |
dc.relation.conference | Finnish mechanics days | |
dc.subject.yso | bentoniitti | |
jyx.subject.uri | http://www.yso.fi/onto/yso/p2464 | |
dc.type.okm | B3 | |