Näytä suppeat kuvailutiedot

dc.contributor.authorTuominen, Juho
dc.contributor.authorLeppänen, Mari
dc.contributor.authorJarske, Heidi
dc.contributor.authorPasanen, Kati
dc.contributor.authorVasankari, Tommi
dc.contributor.authorParkkari, Jari
dc.date.accessioned2023-03-20T05:40:09Z
dc.date.available2023-03-20T05:40:09Z
dc.date.issued2023
dc.identifier.citationTuominen, J., Leppänen, M., Jarske, H., Pasanen, K., Vasankari, T., & Parkkari, J. (2023). Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro. <i>Methods and Protocols</i>, <i>6</i>(2), Article 26. <a href="https://doi.org/10.3390/mps6020026" target="_blank">https://doi.org/10.3390/mps6020026</a>
dc.identifier.otherCONVID_177369607
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/86030
dc.description.abstractBackground: The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated. Objective: To examine the test−retest reliability of isokinetic ankle plantar and dorsiflexion, ankle inversion and eversion, knee extension and flexion and hip abduction and adduction strength in physically active adults using Biodex System 4 Pro. Methods: Peak torques (PTs) and average peak torques (APTs) of the dominant and nondominant lower limbs were tested twice in 19 physically active adults 7 to 14 days apart. Results: The intraclass correlation coefficients (ICC) values varied from excellent to moderate and coefficient of variation of typical error (CVTE) values were 6.6–19.5%. Change in the mean expressed as a percent varied from −3.1% to 9.6%. There was no difference in the reliability between PT and APT values. Dominant lower limb was more reliable in every case if there was difference between limbs. Conclusion: Test−retest reliability of isokinetic ankle, knee and hip strength in physically active adults using Biodex System 4 is mostly good or excellent. However, the observed range of the random variation has to be noted when using it in scientific follow-up studies or evaluation of patient progress in clinical settings.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherMDPI AG
dc.relation.ispartofseriesMethods and Protocols
dc.rightsCC BY 4.0
dc.subject.otherisokineettinen dynamometri
dc.subject.otherisokinetic
dc.subject.otherdynamometry
dc.subject.otherBiodex
dc.subject.othertest−retest
dc.subject.otherreliability
dc.subject.otherankle
dc.subject.otherknee
dc.subject.otherhip
dc.titleTest−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
dc.typearticle
dc.identifier.urnURN:NBN:fi:jyu-202303202182
dc.contributor.laitosLiikuntatieteellinen tiedekuntafi
dc.contributor.laitosFaculty of Sport and Health Sciencesen
dc.type.urihttp://purl.org/eprint/type/JournalArticle
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1
dc.description.reviewstatuspeerReviewed
dc.relation.issn2409-9279
dc.relation.numberinseries2
dc.relation.volume6
dc.type.versionpublishedVersion
dc.rights.copyright© 2023 by the authors. Licensee MDPI, Basel, Switzerland.
dc.rights.accesslevelopenAccessfi
dc.subject.ysolonkka
dc.subject.ysonilkat
dc.subject.ysoreliabiliteetti
dc.subject.ysomittauslaitteet
dc.subject.ysopolvet
dc.subject.ysolihasvoima
dc.subject.ysomittausmenetelmät
dc.format.contentfulltext
jyx.subject.urihttp://www.yso.fi/onto/yso/p7232
jyx.subject.urihttp://www.yso.fi/onto/yso/p24005
jyx.subject.urihttp://www.yso.fi/onto/yso/p9970
jyx.subject.urihttp://www.yso.fi/onto/yso/p3583
jyx.subject.urihttp://www.yso.fi/onto/yso/p14204
jyx.subject.urihttp://www.yso.fi/onto/yso/p23362
jyx.subject.urihttp://www.yso.fi/onto/yso/p20083
dc.rights.urlhttps://creativecommons.org/licenses/by/4.0/
dc.relation.doi10.3390/mps6020026
jyx.fundinginformationWe acknowledge the funding from Finnish Ministry of Education and Culture, and the Competitive State Research Financing of the Expert Responsibility Area of Tampere University Hospital (Grant 9AB055).
dc.type.okmA1


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot

CC BY 4.0
Ellei muuten mainita, aineiston lisenssi on CC BY 4.0