Näytä suppeat kuvailutiedot

dc.contributor.advisorLeroux, Paul
dc.contributor.advisorDilillo, Luigi
dc.contributor.authorLim, Nadia
dc.date.accessioned2024-09-23T06:22:26Z
dc.date.available2024-09-23T06:22:26Z
dc.date.issued2024
dc.identifier.urihttps://jyx.jyu.fi/handle/123456789/97146
dc.description.abstractThis study investigates the performance of a Successive Approximation Register (SAR) Analog-to-Digital Converter (ADC) under Total Ionizing Dose (TID) conditions, identifying the TID-sensitive blocks and their impact on overall performance. TID models were developed to simulate two primary effects: threshold voltage shifts in the comparator and leakage current increase in the sampling and capacitor digital-to-analog converter (CDAC) switches. Models were developed based on experimental data from literature, and using a combination of Berkeley Short-Channel IGFET Model (BSIM) device modeling and circuit-level modeling. SPICE simulations, employing transient and spectral analyses, revealed that threshold voltage shifts in the comparator have minimal impact on noise characteristics and overall performance due to the comparator's robust design features. Conversely, leakage effects in the sampling and CDAC switches caused slight deviations in the output signal due to erroneous voltages generated through the switches, resulting in significant degradation in the ADC performance parameters. Combined TID effects revealed further performance degradation due to compounded errors resulting from erroneous voltages fed to the comparator and the TID-induced on-resistance variability of the sampling switches. Results from this analysis provide valuable insights into the SAR ADC's suitability for space applications and highlights the critical effects in the design blocks that significantly impact overall ADC performance under radiation.en
dc.format.extent38
dc.language.isoen
dc.subject.othertotal ionizing dose
dc.subject.othersuccessive approximation register
dc.subject.otherspace application
dc.subject.othersar adc
dc.titleTotal ionizing dose analysis of SAR ADC for space applications
dc.identifier.urnURN:NBN:fi:jyu-202409236023
dc.type.ontasotMaster’s thesisen
dc.type.ontasotPro gradu -tutkielmafi
dc.contributor.tiedekuntaMatemaattis-luonnontieteellinen tiedekuntafi
dc.contributor.tiedekuntaFaculty of Sciencesen
dc.contributor.laitosFysiikan laitosfi
dc.contributor.laitosDepartment of Physicsen
dc.contributor.yliopistoJyväskylän yliopistofi
dc.contributor.yliopistoUniversity of Jyväskyläen
dc.contributor.oppiaineElektroniikkafi
dc.contributor.oppiaineElectronicsen
dc.rights.copyrightJulkaisu on tekijänoikeussäännösten alainen. Teosta voi lukea ja tulostaa henkilökohtaista käyttöä varten. Käyttö kaupallisiin tarkoituksiin on kielletty.fi
dc.rights.copyrightThis publication is copyrighted. You may download, display and print it for Your own personal use. Commercial use is prohibited.en
dc.contributor.oppiainekoodi4022
dc.subject.ysomikroelektroniikka
dc.subject.ysoelektroniikka
dc.subject.ysosäteily
dc.subject.ysomicroelectronics
dc.subject.ysoelectronics
dc.subject.ysoradiation


Aineistoon kuuluvat tiedostot

Thumbnail

Aineisto kuuluu seuraaviin kokoelmiin

Näytä suppeat kuvailutiedot